COMPARATIVE PERFORMANCE OF 5 COMMERCIAL PRICK SKIN-TEST DEVICES

被引:87
作者
NELSON, HS
ROSLONIEC, DM
MCCALL, LI
IKLE, D
机构
[1] Department of Medicine, National Jewish Center for Immunology and Respiratory Medicine Denver, CO
关键词
SKIN TESTS; DEVICES; PRICK; PUNCTURE; FALSE POSITIVE; FALSE NEGATIVE; REPRODUCIBILITY;
D O I
10.1016/0091-6749(93)90019-C
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Five commercially available devices for performing prick skin testing were compared for reproducibility, patient acceptance, occurrence of false-negative skin test results, and size distribution of reactions at the negative control sites. Reproducibility of skin testing with 10 mg/ml histamine base, as expressed by coefficient of variation, was similar. However a clear range of trauma to the skin was produced by the devices. This trauma was least with the Hollister-Stier and ALK Laboratories lancets, intermediate for the bifurcated needle by either prick or puncture, and greatest for the Multi-Test and DermaPIK devices. The more traumatic devices produced larger mean wheals and more frequent and large reactions at saline control sites, and were less acceptable to subjects. However, except for the Multi- Test device, they less often yielded false-negative responses. It is proposed that for each device a different size of wheal must be produced at the allergen site to have confidence that it exceeds the control site. The wheal size necessary for 99% specificity were as follows: Hollister-Stier lancet, 2 mm; ALK lancet, 3.0 mm; bifurcated needle prick, 4.0 mm; bifurcated needle puncture, 4.5 mm; Multi-Test device, 5.0 mm; and DermaPIK device, 5.5 mm. An additional observation was the presence of a significant gradient of reaction size on the back to both histamine and allergen (p < 0.0001), with the smallest reactions in the upper third and the largest in the lower third of the back.
引用
收藏
页码:750 / 756
页数:7
相关论文
共 20 条
[1]   A COMPARISON OF 6 EPICUTANEOUS DEVICES IN THE PERFORMANCE OF IMMEDIATE HYPERSENSITIVITY SKIN TESTING [J].
ADINOFF, AD ;
ROSLONIEC, DM ;
MCCALL, LL ;
NELSON, HS .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1989, 84 (02) :168-174
[2]   STANDARDIZATION OF THE PRICK TEST - A COMPARATIVE-STUDY OF 3 METHODS [J].
BASOMBA, A ;
SASTRE, A ;
PELAEZ, A ;
ROMAR, A ;
CAMPOS, A ;
GARCIAVILLALMANZO, A .
ALLERGY, 1985, 40 (06) :395-399
[3]   EVALUATION OF THE MULTITEST DEVICE FOR IMMEDIATE HYPERSENSITIVITY SKIN TESTING [J].
BERKOWITZ, RB ;
TINKELMAN, DG ;
LUTZ, C ;
CRUMMIE, A ;
SMITH, K .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 90 (06) :979-985
[4]   RELATIONSHIP OF RESPIRATORY ALLERGY, SKIN-TEST REACTIVITY, AND SERUM IGE IN A COMMUNITY POPULATION-SAMPLE [J].
BROWN, WG ;
HALONEN, MJ ;
KALTENBORN, WT ;
BARBEE, RA .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1979, 63 (05) :328-335
[5]   PRECISION OF SKIN PRICK AND PUNCTURE TESTS WITH 9 METHODS [J].
DEMOLY, P ;
BOUSQUET, J ;
MANDERSCHEID, JC ;
DREBORG, S ;
DHIVERT, H ;
MICHEL, FB .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1991, 88 (05) :758-762
[6]  
DREBORG S, 1989, ALLERGY S10, V44, P23
[7]   COMPARISON OF THE SENSITIVITY AND PRECISION OF 4 SKIN-TEST DEVICES [J].
ENGLER, DB ;
DEJARNATT, AC ;
SIM, TC ;
LEE, JL ;
GRANT, JA .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 90 (06) :985-991
[8]  
GARIBALDI E, 1990, ANN ALLERGY, V65, P481
[9]   MULTITEST VERSUS MORROW BROWN NEEDLE [J].
MAHAN, C ;
SPECTOR, SL ;
SIEGEL, SC ;
KATZ, RM ;
RACHELEFSKY, GS ;
ROHR, AS .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1990, 86 (02) :275-276
[10]   THE ALLERGY PRICKER - QUALITATIVE ASPECTS OF SKIN PRICK TESTING USING A PRECISION NEEDLE [J].
MALLING, HJ ;
ANDERSEN, CE ;
BOAS, B ;
HOLGERSEN, F ;
MUNCH, EP ;
WEEKE, B .
ALLERGY, 1982, 37 (08) :563-567