MOTION-INDUCED PHASE-SHIFTS IN MR - ACCELERATION EFFECTS IN QUANTITATIVE FLOW MEASUREMENTS - A RECONSIDERATION

被引:37
作者
KOUWENHOVEN, M
HOFMAN, MBM
SPRENGER, M
机构
[1] FREE UNIV AMSTERDAM HOSP, DEPT CLIN PHYS & ENGN, AMSTERDAM, NETHERLANDS
[2] FREE UNIV AMSTERDAM, PHYSIOL LAB, AMSTERDAM, NETHERLANDS
关键词
MAGNETIC RESONANCE; PHASE; FLOW; ACCELERATION;
D O I
10.1002/mrm.1910330605
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance phase difference techniques are commonly used to study flow velocities in the human body, Acceleration is often present, either in the form of pulsatile flow, or in the form of convective acceleration. Questions have arisen about the exact time point at which the velocity is encoded, and also about the sensitivity to (convective) acceleration and higher order motion derivatives. It has become common practice to interpret the net phase shifts measured with a phase difference velocity technique as being the velocity at a certain (Taylor) expansion time point, chosen somewhere between the RF excitation and the echo readout. However, phase shifts are developed over the duration of the encoding magnetic field gradient wave form, and should therefore be interpreted as a more or less time-averaged velocity. It will be shown that the phase shift as measured with a phase difference velocity technique represents the velocity at the "gravity" center of the encoding bipolar gradient (difference) function, without acceleration contribution. Any attempt to interpret the measured phase shift in terms of velocity on any other time point than the gradient gravity point will automatically introduce acceleration sensitivity.
引用
收藏
页码:766 / 777
页数:12
相关论文
共 37 条
[1]  
[Anonymous], 1989, HEMODYNAMICS
[2]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[3]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[4]  
CONSTANTINESCO A, 1984, Magnetic Resonance Imaging, V2, P335, DOI 10.1016/0730-725X(84)90200-5
[5]   MODIFIED GRADIENTS FOR MOTION SUPPRESSION - VARIABLE ECHO TIME AND VARIABLE BANDWIDTH [J].
DUERK, JL ;
SIMONETTI, OP ;
HURST, GC .
MAGNETIC RESONANCE IMAGING, 1990, 8 (02) :141-151
[6]   MULTIECHO MULTIMOMENT REFOCUSING OF MOTION IN MAGNETIC-RESONANCE-IMAGING - MEM-MO-RE [J].
DUERK, JL ;
SIMONETTI, OP ;
HURST, GC ;
MOTTA, AO .
MAGNETIC RESONANCE IMAGING, 1990, 8 (05) :535-541
[7]   EXPERIMENTAL CONFIRMATION OF PHASE-ENCODING OF INSTANTANEOUS DERIVATIVES OF POSITION [J].
DUERK, JL ;
SIMONETTI, OP ;
HURST, GC ;
FINELLI, DA .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :77-87
[8]  
DUERK JL, 1993, MAGNETIC RESONANCE A, P80
[9]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[10]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241