REDUCTION OF UNNECESSARY INTRAVENOUS CATHETER USE - INTERNAL-MEDICINE HOUSE STAFF PARTICIPATE IN A SUCCESSFUL QUALITY IMPROVEMENT PROJECT

被引:79
作者
PARENTI, CM
LEDERLE, FA
IMPOLA, CL
PETERSON, LR
机构
[1] MINNEAPOLIS VET AFFAIRS MED CTR,QUAL MANAGEMENT OFF,MINNEAPOLIS,MN
[2] NORTHWESTERN UNIV,NW MEM HOSP,DEPT PATHOL,CHICAGO,IL 60611
关键词
D O I
10.1001/archinte.154.16.1829
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We had previously observed that a large proportion of peripheral intravenous (IV) catheters placed in patients on a regular medical ward at our hospital were unnecessary. We conducted the current study to assess the effect of a quality improvement project led by medicine house staff on the prevalence of unnecessary peripheral IV catheters (those without any therapeutic use, referred to as idle). Methods: All patients on four regular-care medical wards of a large university-affiliated veterans hospital were included in the study. The proportion of IV catheter episodes in which catheters were idle 2 or more consecutive days (idle episodes) and the proportion of patients exposed to an idle catheter episode were determined by direct observation, chart review, and patient interview before and after a multidisciplinary quality improvement task force defined guidelines for appropriate IV catheter use and made recommendations for hospital policy changes related to IV catheter use. Results: The proportion of all IV catheter episodes that were idle catheter episodes decreased significantly after the intervention (42% before vs 29% after, P<.01),as did the proportion of patients with an IV catheter who had at least one idle IV catheter eipsode (43% vs 27%, P<.001). Conclusions: This quality improvement effort successfully reduced unnecessary IV catheter use. We suspect that house-staff involvement in the intervention was critical. We encourage other academic medical centers to involve house staff in quality improvement activities to improve patient care and to enhance the education of house staff regarding quality improvement processes.
引用
收藏
页码:1829 / 1832
页数:4
相关论文
共 16 条
[1]   SYSTEMIC SEPSIS AND INTRAVENOUS DEVICES - A PROSPECTIVE SURVEY [J].
COLLIGNON, PJ ;
MUNRO, R ;
SORRELL, TC .
MEDICAL JOURNAL OF AUSTRALIA, 1984, 141 (06) :345-348
[2]  
ETZEL SI, 1992, REV SPECIAL REQUIREM, V93, P44
[3]  
GOLDMANN DA, 1973, ANN INTERN MED, V79, P848, DOI 10.7326/0003-4819-79-6-848
[4]   RATES OF NEEDLE-STICK INJURY CAUSED BY VARIOUS DEVICES IN A UNIVERSITY HOSPITAL [J].
JAGGER, J ;
HUNT, EH ;
BRANDELNAGGAR, J ;
PEARSON, RD .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (05) :284-288
[5]   GUIDELINE-BASED CONSULTATION TO PREVENT ANTICOAGULANT-RELATED BLEEDING - A RANDOMIZED, CONTROLLED TRIAL IN A TEACHING HOSPITAL [J].
LANDEFELD, CS ;
ANDERSON, PA .
ANNALS OF INTERNAL MEDICINE, 1992, 116 (10) :829-837
[6]   THE IDLE INTRAVENOUS CATHETER [J].
LEDERLE, FA ;
PARENTI, CM ;
BERSKOW, LC ;
ELLINGSON, KJ .
ANNALS OF INTERNAL MEDICINE, 1992, 116 (09) :737-738
[7]   GAUZE VS PLASTIC FOR PERIPHERAL INTRAVENOUS DRESSINGS - TESTING A NEW TECHNOLOGY [J].
LITTENBERG, B ;
THOMPSON, L .
JOURNAL OF GENERAL INTERNAL MEDICINE, 1987, 2 (06) :411-414
[8]   RISK-FACTORS FOR INFUSION-RELATED PHLEBITIS WITH SMALL PERIPHERAL VENOUS CATHETERS - A RANDOMIZED CONTROLLED TRIAL [J].
MAKI, DG ;
RINGER, M .
ANNALS OF INTERNAL MEDICINE, 1991, 114 (10) :845-854
[9]   A COMPARATIVE-STUDY OF POLYANTIBIOTIC AND IODOPHOR OINTMENTS IN PREVENTION OF VASCULAR CATHETER-RELATED INFECTION [J].
MAKI, DG ;
BAND, JD .
AMERICAN JOURNAL OF MEDICINE, 1981, 70 (03) :739-744
[10]   EVALUATION OF DRESSING REGIMENS FOR PREVENTION OF INFECTION WITH PERIPHERAL INTRAVENOUS CATHETERS - GAUZE, A TRANSPARENT POLYURETHANE DRESSING, AND AN IODOPHOR-TRANSPARENT DRESSING [J].
MAKI, DG ;
RINGER, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 258 (17) :2396-2403