SHAPE SELECTIVITY ASSESSMENT OF STATIONARY PHASES IN GAS-CHROMATOGRAPHY

被引:27
作者
SANDER, LC
SCHNEIDER, M
WISE, SA
WOOLLEY, C
机构
[1] UNIV ULM, DEPT ANALYT & ENVIRONM CHEM, W-7900 ULM, GERMANY
[2] SUPELCO INC, BELLEFONTE, PA 16823 USA
关键词
GAS CHROMATOGRAPHY; STATIONARY PHASES; LIQUID CRYSTAL POLYSILOXANE; C(18) POLYSILOXANE; SHAPE SELECTIVITY; POLYCYCLIC AROMATIC HYDROCARBONS;
D O I
10.1002/mcs.1220060205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Column selectivity is examined for a series of smectic liquid crystalline columns and is compared with methyl and C18 polysiloxane columns for the separation of polycyclic aromatic hydrocarbon (PAH) isomers. A set of e,tended and condensed solute probes is described that provides a sensitive indication of variations in column shape selectivity. Examples of shape selectivity differences are presented for smectic liquid crystalline columns and 5% phenyl polysiloxane columns using various PAH isomer sets. Variations in selectivity have been observed among different smectic liquid crystalline columns, and this problem appears more significant than for methyl polysiloxane columns. The selectivity ratio for tetraphenylmethane and p-terphenyl provides a sensitive indication of column shape selectivity, with a change in elution order occurring between ordered (smectic liquid crystalline) columns and non-ordered (methyl polysiloxane) columns. Shape selectivity differences indicated by this test mixture are apparent for more complex PAH isomer mixtures. Despite stationary phase selectivity variability, smectic liquid crystalline columns offer considerable potential for solving difficult separation problems involving structured solutes.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 34 条
[11]   SEPARATION OF 12 MONOMETHYLBENZ[A]ANTHRACENES ON THE LIQUID-CRYSTAL AND ISOTROPIC STATIONARY PHASES IN RELATION TO THE SHAPE OF THEIR MOLECULES [J].
LAMPARCZYK, H .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (02) :90-92
[12]   QUALITATIVE AND QUANTITATIVE-ANALYSES OF COMMERCIAL POLYCHLORINATED BIPHENYL FORMULATION MIXTURES BY SINGLE ION MONITORING GAS-LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY AND MULTIPLE-REGRESSION [J].
LIU, RH ;
RAMESH, S ;
LIU, JY ;
KIM, S .
ANALYTICAL CHEMISTRY, 1984, 56 (11) :1808-1812
[13]   SMECTIC BIPHENYLCARBOXYLATE ESTER LIQUID-CRYSTALLINE POLYSILOXANE STATIONARY PHASE FOR CAPILLARY GAS-CHROMATOGRAPHY [J].
MARKIDES, KE ;
NISHIOKA, M ;
TARBET, BJ ;
BRADSHAW, JS ;
LEE, ML .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1296-1299
[14]   RELATIONSHIP BETWEEN THE RETENTION INDEXES ON NEMATIC AND ISOTROPIC PHASES AND THE SHAPE OF POLYCYCLIC AROMATIC-HYDROCARBONS [J].
RADECKI, A ;
LAMPARCZYK, H ;
KALISZAN, R .
CHROMATOGRAPHIA, 1979, 12 (09) :595-599
[15]   IMPROVED CONGENER-SPECIFIC SEPARATION OF 2,3,7,8-TYPE POLYCHLORODIBENZODIOXINS (PCDD) AND POLYCHLORODIBENZOFURANS (PCDF) BY COLUMN COUPLING IN GAS-CHROMATOGRAPHY [J].
RIEHLE, U ;
BALLSCHMITER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07) :744-744
[16]   EVALUATION OF COLUMN PERFORMANCE IN LIQUID-CHROMATOGRAPHY [J].
SANDER, LC .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1988, 26 (08) :380-387
[17]  
SANDER LC, 1990, LC GC-MAG SEP SCI, V8, P378
[18]   DETERMINATION OF COLUMN SELECTIVITY TOWARD POLYCYCLIC AROMATIC-HYDROCARBONS [J].
SANDER, LC ;
WISE, SA .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (05) :383-387
[19]   SHAPE SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF PLANAR AND NONPLANAR SOLUTES [J].
SANDER, LC ;
WISE, SA .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :335-351
[20]   SUBAMBIENT TEMPERATURE MODIFICATION OF SELECTIVITY IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
SANDER, LC ;
WISE, SA .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1749-1754