COMPARISON OF 2 2ND-GENERATION ANTI-HEPATITIS-C VIRUS ELISA ON 21431 US BLOOD-DONOR SAMPLES

被引:57
作者
ANDERSON, SC
HATHAWAY, T
KURAMOTO, IK
HOLLAND, PV
GILCHER, R
KOCH, T
HOJVAT, S
机构
[1] OKLAHOMA BLOOD INST,OKLAHOMA CITY,OK
[2] ABBOTT LABS,CHICAGO,IL
关键词
ANTI-HCV; BLOOD DONOR; ENZYME IMMUNOASSAY; HEPATITIS C; HEPATITIS C ANTIBODY; RECOMBINANT IMMUNOBLOT ASSAY;
D O I
10.1111/j.1365-2893.1995.tb00072.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
We have compared two different second-generation (2.0) enzyme-linked immunosorbent assays (ELISA) for the presence of antibodies to hepatitis C virus (anti-HCV) in blood from volunteer, unpaid donors. At two separate blood centres, a total of 21431 donor samples were tested with Abbott Anti-HCV 2.0 ELISA and Ortho Anti-HCV 2.0 ELISA. Samples found to be repeatedly reactive were tested by supplemental/investigational assays, MATRIX HCV (Abbott) and anti-HCV RIBA II (Ortho/Chiron), to 'confirm' the presence of anti-HCV. Discordant ELISA samples were additionally tested by the polymerase chain reaction (PCR) for the presence of HCV RNA. The Abbott anti-HCV assay had a repeatedly reactive rate of 0.59% (127/21431) and the Ortho anti-HCV assay 0.51% (110/21431). Overall agreement between assays was 99.76%. 72/127 (56.7%) of Abbott repeatedly reactive samples confirmed on MATRIX and 61/127 (48.0%) on RIBAII; 70/110 (63 . 6%) of Ortho repeatedly reactivate samples confirmed on MATRIX and 61/110 (55.5%) on RIBA II, Discordant ELISA samples tested by PCR yielded negative results. Hence the two ELISA had equal sensitivity, as defined by detection of true positive samples; the slightly lower specificity of the Abbott Anti-HCV 2.0 ELISA may be owing to culling of donors with a false positive test by Ortho's Anti-HCV 1.0 and 2.0 ELISA tests (the routine tests in place at each blood centre). A sample found to be repeatedly reactive by two different ELISA tests for anti-HCV is likely to be a true positive and may not require further 'confirmatory' testing.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 16 条
[11]   SPECIFICITY AND SENSITIVITY OF 2 2ND-GENERATION ELISA TESTS IN DETECTING HEPATITIS-C ANTIBODIES IN BLOOD-DONORS KNOWN TO BE REACTIVE WITH A SUPPLEMENTAL ASSAY [J].
KOLHO, E ;
NAUKKARINEN, R ;
KRUSIUS, T .
VOX SANGUINIS, 1992, 63 (02) :158-160
[12]  
KUHUS M, 1994, J AM SOC NEPHROL, V4, P1491
[13]   A COMPARISON OF 2 SUPPLEMENTAL PROCEDURES FOR CONFIRMATION OF ANTIBODY TO HEPATITIS-C VIRUS C100-3 ANTIGEN IN LOUISIANA BLOOD-DONORS [J].
SMITH, D ;
DELANEY, S ;
ALLAIN, JP ;
VALLARI, D ;
LEE, H .
TRANSFUSION, 1992, 32 (05) :415-419
[14]   SEROLOGICAL MARKERS OF POSTTRANSFUSION HEPATITIS-C VIRAL-INFECTION [J].
VALLARI, DS ;
JETT, BW ;
ALTER, HJ ;
MIMMS, LT ;
HOLZMAN, R ;
SHIH, JWK .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (03) :552-556
[15]   CONFIRMATION OF HEPATITIS-C VIRUS-INFECTION BY NEW 4-ANTIGEN RECOMBINANT IMMUNOBLOT ASSAY [J].
VANDERPOEL, CL ;
CUYPERS, HTM ;
REESINK, HW ;
WEINER, AJ ;
QUAN, S ;
DINELLO, R ;
VANBOVEN, JJP ;
WINKEL, I ;
MULDERFOLKERTS, D ;
EXELOEHLERS, PJ ;
SCHAASBERG, W ;
LEENTVAARKUYPERS, A ;
POLITO, A ;
HOUGHTON, M ;
LELIE, PN .
LANCET, 1991, 337 (8737) :317-319
[16]   HEPATITIS-C VIRUS-RNA IN SALIVA OF PATIENTS WITH POSTTRANSFUSION HEPATITIS-C INFECTION [J].
WANG, JT ;
WANG, TH ;
LIN, JT ;
SHEU, JC ;
LIN, SM ;
CHEN, DS .
LANCET, 1991, 337 (8732) :48-48