Lack of Reactivity During Pedometer Self-Monitoring in Adults

被引:41
作者
Matevey, Courtney [1 ]
Rogers, Laura Q. [1 ]
Dawson, Elizabeth [1 ]
Tudor-Locke, Catrine [2 ]
机构
[1] Southern Illinois Univ, Sch Med, Dept Med, POB 19636, Springfield, IL 62794 USA
[2] Arizona State Univ East, Dept Exercise & Wellness, Mesa, AZ USA
关键词
exercise; measurement; assessment;
D O I
10.1207/s15327841mpee1001_1
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
The study purpose was to determine whether unsealed (with participant recording of daily steps) versus sealed pedometer monitoring elicits reactivity (i.e., changed behavior due to awareness of being monitored) in adults. In a randomized controlled crossover study, 28 healthy White adults (12 men, M age = 51 +/- 9.9 years; and 16 women, M age = 44 +/- 6.5 years) completed 2 assessment types (sealed versus unsealed pedometer). Half of the participants wore a sealed pedometer for 1 week, submitting it for reading by research staff. After a 2-week washout, the participants wore an unsealed pedometer, recording total daily steps for 1 week. The remaining participants completed the protocol in reverse order. Analyses included a repeated measures analysis of variance (ANOVA) using condition (mean steps per day for sealed versus unsealed) as the repeated variable and gender and order of assessment type as the between variables. There was no significant difference between sealed versus unsealed pedometers in steps per day, F(1, 24) = 0.51, p =.48, regardless of gender, F(1, 24) = 0.13, p =.72, or order of assessment type, F(1, 24) =.48, p =.50. The intraclass correlation coefficient (ICC) between average steps per day for the sealed versus unsealed assessment was.84, p <.0001, confirming strong repeatability (i.e., individuals hold their rank order within the group regardless of condition type). Reactivity does not appear to be an important threat to validity of pedometer self-monitoring in free-living healthy adults.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 27 条
[1]   Accuracy of five electronic pedometers for measuring distance walked [J].
Bassett, DR ;
Ainsworth, BE ;
Leggett, SR ;
Mathien, CA ;
Main, JA ;
Hunter, DC ;
Duncan, GE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) :1071-1077
[2]  
Centers for Disease Control and Prevention (CDC), 2000, MMWR Morb Mortal Wkly Rep, V49, P326
[3]  
Centers for Disease Control and Prevention (CDC), 2000, MMWR Morb Mortal Wkly Rep, V49, P560
[4]   Health benefits of a pedometer-based physical activity intervention in sedentary workers [J].
Chan, CB ;
Ryan, DAJ ;
Tudor-Locke, C .
PREVENTIVE MEDICINE, 2004, 39 (06) :1215-1222
[5]  
Cohen J., 2013, STAT POWER ANAL BEHA
[6]   A preliminary study on the impact of a pedometer-based intervention on daily steps [J].
Croteau, KA .
AMERICAN JOURNAL OF HEALTH PROMOTION, 2004, 18 (03) :217-220
[7]   Validity of 10 electronic pedometers for measuring steps, distance, and energy cost [J].
Crouter, SE ;
Schneider, PL ;
Karabulut, M ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1455-1460
[8]   Does augmented feedback from pedometers increase adults' walking behavior? [J].
Eastep, E ;
Beveridge, S ;
Eisenman, P ;
Ransdell, L ;
Shultz, B .
PERCEPTUAL AND MOTOR SKILLS, 2004, 99 (02) :392-402
[9]   Prevalence and trends in obesity among US adults, 1999-2000 [J].
Flegal, KM ;
Carroll, MD ;
Ogden, CL ;
Johnson, CL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (14) :1723-1727
[10]   Motion sensor accuracy under controlled and free-living conditions [J].
Le Masurier, GC ;
Lee, SM ;
Tudor-Locke, C .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05) :905-910