THE PULSED GLOW-DISCHARGE AS AN ELEMENTAL ION-SOURCE

被引:58
作者
KLINGLER, JA [1 ]
SAVICKAS, PJ [1 ]
HARRISON, WW [1 ]
机构
[1] UNIV FLORIDA,DEPT CHEM,GAINESVILLE,FL 32611
关键词
D O I
10.1016/1044-0305(90)85049-R
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A pulsed glow discharge, rather than a conventional constant dc voltage discharge, is used as an ion source for a quadrupole mass spectrometer. Both sputter yield and ion signal are enhanced by using the pulsed system because of an increase in the voltage necessary to maintain a constant average current at the cathode over the pulse period. Irregularities are seen in the pulse spectrum that appear as rapid surges in the ion signal for both sputtered and contaminant gas species. These peaks appear at the beginning of the pulse for gaseous species but are limited to the postpulse period for sputtered species. Differences in the signal forms allow for the discrimination against selected types of ion signals by using narrow data collection gates placed over different portions of the pulse period. © 1990 American Society for Mass Spectrometry.
引用
收藏
页码:138 / 143
页数:6
相关论文
共 16 条
[1]   COMPARISON OF ATOMIC FLUORESCENCE WITH ATOMIC-ABSORPTION AS AN ANALYTICAL TECHNIQUE [J].
BARNETT, WB ;
KAHN, HL .
ANALYTICAL CHEMISTRY, 1972, 44 (06) :935-&
[2]   SIMPLIFIED SOLIDS MASS-SPECTROMETER COMBINING A GLOW-DISCHARGE SOURCE WITH A QUADRUPOLE MASS FILTER [J].
BRUHN, CG ;
BENTZ, BL ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1978, 50 (02) :373-375
[3]  
Chapman B., 1980, GLOW DISCHARGE PROCE, P394
[4]  
COBINE CD, 1958, GASEOUS CONDUCTORS, P207
[5]   PLASMA DIAGNOSTICS OF AN RF-SPUTTERING GLOW DISCHARGE [J].
COBURN, JW ;
KAY, E .
APPLIED PHYSICS LETTERS, 1971, 18 (10) :435-&
[6]   ION ENERGIES AT CATHODE OF A GLOW DISCHARGE [J].
DAVIS, WD ;
VANDERSLICE, TA .
PHYSICAL REVIEW, 1963, 131 (01) :219-&
[7]   PULSED CURRENT OPERATION OF HOLLOW CATHODE LAMPS TO INCREASE INTENSITY OF RESONANCE LINES FOOR ATOMIC ABSORPTION SPECTROSCOPY [J].
DAWSON, JB ;
ELLIS, DJ .
SPECTROCHIMICA ACTA PART A-MOLECULAR SPECTROSCOPY, 1967, A 23 (03) :565-&
[8]   TIME-RESOLVED AND WAVELENGTH-RESOLVED EMISSION-LINE PROFILES FOR PULSED CU AND AG HOLLOW-CATHODE LAMPS [J].
DEJONG, GJ ;
PIEPMEIER, EH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1974, B 29 (06) :159-177
[9]   METASTABLE ATOM DENSITY IN HELIUM, NEON, AND ARGON GLOW-DISCHARGES [J].
HARDY, KA ;
SHELDON, JW .
JOURNAL OF APPLIED PHYSICS, 1982, 53 (12) :8532-8536
[10]  
HARRISON WW, 1988, PROG ANAL SPECTROSC, V11, P53