ANGIOARCHITECTURE OF PULMONARY ARTERIOVENOUS-MALFORMATIONS - CLINICAL UTILITY OF 3-DIMENSIONAL HELICAL CT

被引:152
作者
REMY, J
REMYJARDIN, M
GIRAUD, F
WATTINNE, L
机构
[1] Department of Radiology, Hôpital Calmette, 59037 Lille, Blvd Jules Leclercq
关键词
ARTERIOVENOUS MALFORMATIONS; PULMONARY; COMPUTED TOMOGRAPHY (CT); HELICAL TECHNOLOGY; 3-DIMENSIONAL;
D O I
10.1148/radiology.191.3.8184042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the clinical utility of three-dimensional (3D) helical computed tomography (CT) in pretherapy evaluation of the angioarchitecture of pulmonary arteriovenous malformations (PAVMs). MATERIALS AND METHODS: Thirty-seven PAVMs were prospectively evaluated with both helical CT and pulmonary angiography. Single-threshold shaded-surface displays were obtained with 2- or 5-mm section thickness, a pitch of 1, and a 360 degrees linear interpolation algorithm but without injection of contrast medium. RESULTS: A reliable analysis of the angioarchitecture of 28 PAVMs (76%)-25 simple and three complex-was provided by 3D reconstructions; combined interpretation of 3D images and transverse sections led to accurate evaluation of 35 PAVMs (95%). Positioning of the target anatomy in the reconstructed volume, threshold value, number of stacked sections, and section thickness influenced the diagnostic information. CONCLUSION: Unenhanced 3D helical CT appears to be a reliable noninvasive tool for pretherapy evaluation of PAVMs.
引用
收藏
页码:657 / 664
页数:8
相关论文
共 20 条
  • [1] SPIRAL CT ANGIOGRAPHY
    DILLON, EH
    VANLEEUWEN, MS
    FERNANDEZ, MA
    MALI, WPTM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) : 1273 - 1278
  • [2] NMR IMAGING OF PULMONARY ARTERIOVENOUS-FISTULAS
    GUTIERREZ, FR
    GLAZER, HS
    LEVITT, RG
    MORAN, JF
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 750 - 752
  • [3] 3-DIMENSIONAL COMPUTERIZED-TOMOGRAPHY ANGIOGRAPHY IN THE DIAGNOSIS OF CEREBROVASCULAR-DISEASE
    HARBAUGH, RE
    SCHLUSSELBERG, DS
    JEFFERY, R
    HAYDEN, S
    CROMWELL, LD
    PLUTA, D
    [J]. JOURNAL OF NEUROSURGERY, 1992, 76 (03) : 408 - 414
  • [4] DIAGNOSIS OF PULMONARY ARTERIOVENOUS-FISTULA BY CONTRAST ECHOCARDIOGRAPHY
    HERNANDEZ, A
    STRAUSS, AW
    MCKNIGHT, R
    HARTMANN, AF
    [J]. JOURNAL OF PEDIATRICS, 1978, 93 (02) : 258 - 261
  • [5] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [6] RAPID 3-DIMENSIONAL SURFACE RECONSTRUCTION OF MAGNETIC-RESONANCE IMAGES OF LARGE ARTERIES AND VEINS - A PRELIMINARY EVALUATION OF CLINICAL UTILITY
    KANDARPA, K
    SANDOR, T
    TIEMAN, J
    HOOSHMAND, R
    CHOPRA, PS
    CHAKRABATI, J
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (01) : 25 - 29
  • [7] ECHOCARDIOGRAPHY AND PERFUSION SCINTIGRAPHY IN DIAGNOSIS OF PULMONARY ARTERIOVENOUS-FISTULA
    LEWIS, AB
    GATES, GF
    STANLEY, P
    [J]. CHEST, 1978, 73 (05) : 675 - 677
  • [8] DIAGNOSIS OF CAROTID-ARTERY DISEASE - PRELIMINARY EXPERIENCE WITH MAXIMUM-INTENSITY-PROJECTION SPIRAL CT ANGIOGRAPHY
    MARKS, MP
    NAPEL, S
    JORDAN, JE
    ENZMANN, DR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) : 1267 - 1271
  • [9] DIAGNOSTIC-IMAGING OF PULMONARY ARTERIOVENOUS-MALFORMATIONS - EVALUATION WITH ROENTGENOGRAPHIC, SONOGRAPHIC, AND RADIONUCLIDE IMAGING
    MOSER, RJ
    TENHOLDER, MF
    [J]. CHEST, 1986, 89 (04) : 586 - 589
  • [10] NAPELS, 1992, RADIOLOGY, V185, P607