COMPARISON OF SCREENING-TESTS FOR NON-INSULIN-DEPENDENT DIABETES-MELLITUS

被引:79
作者
HANSON, RL
NELSON, RG
MCCANCE, DR
BEART, JA
CHARLES, MA
PETTITT, DJ
KNOWLER, WC
机构
关键词
D O I
10.1001/archinte.153.18.2133
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Screening for non-insulin-dependent diabetes mellitus (NIDDM) can be useful in clinical practice and in epidemiologic and genetic studies but the available information for choosing between screening methods is limited. In this study, characteristics of several screening tests for NIDDM were compared. Methods: Among Pima Indians participating in an epidemiologic study, the sensitivity and specificity for detecting NIDDM of fasting plasma glucose (FPG) levels and two measures of glycated hemoglobin (HbA1 or HbA1c) were compared in 2092 fasting subjects. Glycated hemoglobin, quantitative glycosuria, and dipstick glycosuria were compared in 237 nonfasting subjects. Diabetes was diagnosed using an oral glucose tolerance test if the 2-hour postload venous plasma glucose concentration was 11.1 mmol/L (200 mg/dL) or greater- The area under the relative operating characteristic curve was used to compare tests. Results: In fasting subjects, the sensitivity for detecting diabetes with 98% specificity was 78.8% for HbA, level of 7.5% or greater, 80.3% for HbA1c level of 6.3% or greater, and 88.0% for FPG level of 6.83 mmol/L (123 mg/dL) or greater. By relative operating characteristic analysis, there were no significant differences between FPG and HbA1c, but FPG was significantly more sensitive than HbA1. In nonfasting subjects the sensitivity at 98% specificity was 92.9% for HbA, level of 7.3% or greater, 80.6% for quantitative urine glucose level of 1.94 mmol/L (35 mg/dL) or greater, and 64.3% for trace or greater of dipstick glycosuria. The area under the relative operating characteristic curve was significantly greater for glycated hemoglobin than for either measure of glycosuria. Conclusions: Although FPG has the best screening properties, HbA1c, HbA1, and quantitative urine glucose also provide high specificity, and approximately 80% sensitivity in detecting NIDDM. The choice of a particular method could depend on cost, convenience, and availability.
引用
收藏
页码:2133 / 2140
页数:8
相关论文
共 41 条
[21]   ISLET CELL ANTIBODIES AND DIABETES-MELLITUS IN PIMA-INDIANS [J].
KNOWLER, WC ;
BENNETT, PH ;
BOTTAZZO, GF ;
DONIACH, D .
DIABETOLOGIA, 1979, 17 (03) :161-164
[22]   GLYCOSYLATED HEMOGLOBIN AS AN ALTERNATIVE TO THE GLUCOSE-TOLERANCE TEST FOR THE DIAGNOSIS OF DIABETES-MELLITUS [J].
LESTER, E ;
FRAZER, AD ;
SHEPHERD, CA ;
WOODROFFE, FJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (JAN) :74-78
[23]   RELATIONSHIP OF GLYCOSYLATED HEMOGLOBIN TO ORAL GLUCOSE-TOLERANCE - IMPLICATIONS FOR DIABETES SCREENING [J].
LITTLE, RR ;
ENGLAND, JD ;
WIEDMEYER, HM ;
MCKENZIE, EM ;
PETTITT, DJ ;
KNOWLER, WC ;
GOLDSTEIN, DE .
DIABETES, 1988, 37 (01) :60-64
[24]  
MENARD L, 1980, CLIN CHEM, V26, P1598
[25]   EFFECTIVENESS OF GLYCOSYLATED HEMOGLOBIN, FASTING PLASMA-GLUCOSE, AND A SINGLE POST LOAD PLASMA-GLUCOSE LEVEL IN POPULATION SCREENING FOR GLUCOSE-INTOLERANCE - THE ISRAEL STUDY OF GLUCOSE-INTOLERANCE, OBESITY AND HYPERTENSION [J].
MODAN, M ;
HALKIN, H ;
KARASIK, A ;
LUSKY, A .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1984, 119 (03) :431-444
[26]   THE VALUE OF GLYCOSYLATED HEMOGLOBIN AS A SUBSTITUTE FOR THE ORAL GLUCOSE-TOLERANCE TEST IN THE DETECTION OF IMPAIRED GLUCOSE-TOLERANCE (IGT) [J].
MOTALA, AA ;
OMAR, MAK .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1992, 17 (03) :199-207
[27]  
NATHAN DM, 1984, CLIN CHEM, V30, P109
[28]  
Sackett D., 1985, CLIN EPIDEMIOLOGY BA, P59
[29]   THE VALUE OF HBA1 AND FRUCTOSAMINE IN PREDICTING IMPAIRED GLUCOSE-TOLERANCE - AN ALTERNATIVE TO OGTT TO DETECT DIABETES-MELLITUS OR GESTATIONAL DIABETES [J].
SALEMANS, THB ;
VANDIEIJENVISSER, MP ;
BROMBACHER, PJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1987, 24 :447-452
[30]   HEMOGLOBIN A1C LEVELS IN A DIABETES DETECTION PROGRAM [J].
SANTIAGO, JV ;
DAVIS, JE ;
FISHER, F .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1978, 47 (03) :578-580