A COMPARISON OF EXTRADURAL AND INTRAPARENCHYMATOUS INTRACRANIAL PRESSURES IN HEAD-INJURED PATIENTS

被引:31
作者
BRUDER, N [1 ]
NZOGHE, P [1 ]
GRAZIANI, N [1 ]
PELISSIER, D [1 ]
GRISOLI, F [1 ]
FRANCOIS, G [1 ]
机构
[1] HOP TIMONE ADULTES,SERV NEUROCHIRURG,F-13385 MARSEILLE 05,FRANCE
关键词
INTRACRANIAL PRESSURE; EXTRADURAL PRESSURE; INTRAPARENCHYMATOUS PRESSURE; MONITORING; HEAD INJURY;
D O I
10.1007/BF01700971
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The reliability of extradural pressure measurements for the measure of intracranial pressure (ICP) is still controversial. This study was undertaken to assess the limits of agreement between extradural and intraparenchymatous pressures using respectively the Plastimed extradural sensor and the Camino fiberoptic system. The study took place in a neurosurgical intensive care unit. Ten head injured patients were included in the study, leading to the comparison of 1032 pairs of hourly ICP values. Although the measures were significantly correlated, there was no agreement between the two methods of ICP monitoring, Extradural pressure was higher than intraparenchymatous pressure (bias 9 mmHg; 95% confidence interval of bias -9.8 to 27.8 mmHg). The lack of agreement between the two methods is probably due to the unreliability of extradural pressure for the measurement of ICP.
引用
收藏
页码:850 / 852
页数:3
相关论文
共 12 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
CHAMBERS IR, 1993, NEUROSURGERY, V33, P866
[3]   EVALUATION OF A FIBEROPTIC INTRACRANIAL-PRESSURE MONITOR [J].
CRUTCHFIELD, JS ;
NARAYAN, RK ;
ROBERTSON, CS ;
MICHAEL, LH .
JOURNAL OF NEUROSURGERY, 1990, 72 (03) :482-487
[4]  
GAMBARDELLA G, 1993, INTRACRANIAL PRESSUR, V8, P82
[5]   INTRA-CRANICAL PRESSURE - TO MONITOR OR NOT TO MONITOR - A REVIEW OF OUR EXPERIENCE WITH SEVERE HEAD-INJURY [J].
NARAYAN, RK ;
KISHORE, PRS ;
BECKER, DP ;
WARD, JD ;
ENAS, GG ;
GREENBERG, RP ;
DASILVA, AD ;
LIPPER, MH ;
CHOI, SC ;
MAYHALL, CG ;
LUTZ, HA ;
YOUNG, HF .
JOURNAL OF NEUROSURGERY, 1982, 56 (05) :650-659
[6]   CONTINUOUS MONITORING OF CEREBRAL TISSUE PRESSURE IN NEUROSURGICAL PRACTICE - EXPERIENCES WITH 100 PATIENTS [J].
PIEK, J ;
BOCK, WJ .
INTENSIVE CARE MEDICINE, 1990, 16 (03) :184-188
[7]   ACCURACY OF DIFFERENT ROUTES OF INTRACRANIAL-PRESSURE (ICP) MONITORING USING MICROTRANSDUCERS [J].
POON, WS ;
LI, AKC .
JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1990, 2 (04) :280-283
[9]  
Statham P, 1993, INTRACRANIAL PRESSUR, VVIII, P7
[10]   A COMPARISON OF INTRAPARENCHYMATOUS AND INTRAVENTRICULAR PRESSURE RECORDING IN CLINICAL-PRACTICE [J].
SUNDBARG, G ;
NORDSTROM, CH ;
MESSETER, K ;
SODERSTROM, S .
JOURNAL OF NEUROSURGERY, 1987, 67 (06) :841-845