MATRIX-ASSISTED LASER DESORPTION USING A FAST-ATOM-BOMBARDMENT ION-SOURCE AND A MAGNETIC MASS-SPECTROMETER

被引:30
作者
ANNAN, RS [1 ]
KOCHLING, HJ [1 ]
HILL, JA [1 ]
BIEMANN, K [1 ]
机构
[1] MIT,DEPT CHEM,CAMBRIDGE,MA 02139
关键词
D O I
10.1002/rcm.1290060415
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A conventional fast-atom bombardment (FAB) ion source was used to achieve matrix-assisted laser desorption (MALD) in a high-mass, double-focusing, magnetic mass spectrometer. The pulsed ion signals generated by irradiation of a mixture of sample and matrix (2,5-dihydroxybenzoic acid) with either a XeF excimer laser (353 nm) or a nitrogen laser (337 nm) were recorded with a focal-plane detector. A resolution (full-width at half maximum) of 4500 was achieved at m/z 1347.7 (the peptide substance P), 2500 for CsI cluster ions at m/z 10 005.7, and 1250 for the isotope cluster of the small protein cytochrome c (horse) [M + H]+ = m/z 12 360 (average). Sensitivity is demonstrated with 11 fmol of substance P. A survey scan is taken to locate the m/z of the sample molecular ion. The segment that contains the sample can then be integrated for a longer time to produce a better signal-to-noise ratio. In addition to higher sensitivity and lower matrix interference, the advantage of MALD over FAB is the former's lower susceptibility to the presence of salts, and competition between hydrophobic and hydrophilic components of a mixture. This feature is demonstrated by the complete MALD spectrum of a crude partial tryptic digest of sperm-whale apomyoglobin, containing 24 peptides, representing the entire sequence of this protein.
引用
收藏
页码:298 / 302
页数:5
相关论文
共 11 条
[1]
GREEN BN, 1991, MASS SPECTROMETRY PE, P109
[2]
HASSELL AM, 1989, J BIOL CHEM, V264, P4948
[3]
DESIGN CONSIDERATIONS, CALIBRATION AND APPLICATIONS OF AN ARRAY DETECTOR FOR A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
HILL, JA ;
BILLER, JE ;
MARTIN, SA ;
BIEMANN, K ;
YOSHIDOME, K ;
SATO, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 92 :211-230
[4]
MATRIX-ASSISTED LASER DESORPTION IONIZATION WITH A MAGNETIC MASS-SPECTROMETER [J].
HILL, JA ;
ANNAN, RS ;
BIEMANN, K .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (09) :395-399
[5]
A VARIABLE DISPERSION ARRAY DETECTOR FOR A TANDEM MASS-SPECTROMETER [J].
HILL, JA ;
BILLER, JE ;
BIEMANN, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 111 :1-25
[6]
LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[7]
PHOTON-INDUCED DISSOCIATION WITH A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
MARTIN, SA ;
HILL, JA ;
KITTRELL, C ;
BIEMANN, K .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (01) :107-109
[8]
AN APPROACH TOWARD THE COMPLETE FAB ANALYSIS OF ENZYMATIC DIGESTS OF PEPTIDES AND PROTEINS [J].
NAYLOR, S ;
FINDEIS, AF ;
GIBSON, BW ;
WILLIAMS, DH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1986, 108 (20) :6359-6363
[9]
FACTORS AFFECTING THE FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRIC ANALYSIS OF PROTEOLYTIC DIGESTS OF PROTEINS [J].
PUCCI, P ;
SEPE, C ;
MARINO, G .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (01) :22-26
[10]
HIGH-PERFORMANCE TANDEM MASS-SPECTROMETRY - CALIBRATION AND PERFORMANCE OF LINKED SCANS OF A 4-SECTOR INSTRUMENT [J].
SATO, K ;
ASADA, T ;
ISHIHARA, M ;
KUNIHIRO, F ;
KAMMEI, Y ;
KUBOTA, E ;
COSTELLO, CE ;
MARTIN, SA ;
SCOBLE, HA ;
BIEMANN, K .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1652-1659