VARIATIONS IN THE POWER OUTPUT OF THE PIEZON-MASTER-400 ULTRASONIC ENDODONTIC UNIT

被引:5
作者
AHMAD, M
ROY, RA
KAMARUDIN, AG
机构
[1] Department of Conservative Dentistry, University of Malaya, Kuala Lumpur
[2] The Applied Physics Laboratory, The University of Washington, Seattle, Washington
[3] Department of Mechanical Engineering, University of Malaya, Kuala Lumpur
关键词
ENDOSONICS; ROOT CANAL INSTRUMENT; ROOT CANAL THERAPY;
D O I
10.1111/j.1365-2591.1994.tb00225.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The present study was undertaken to see if there was any variability in the power output of Piezon-Master 400 ultrasonic files when driven using different generators, tranducers and file holders. The displacement amplitude of the oscillating tip of the file in air was used as a measure of the power output. The results showed that there was considerable variability in the power output of Piezon-Master 400 ultrasonic files of similar size and length when driven using different generators, transducers and file holders. In consideration of this, it is recommended that a calibration device be incorporated in the ultrasonic unit so that the operator will have some knowledge of when the unit is working at its maximum efficiency.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 12 条
[1]  
Ahmad M, Some observations on the mechanics of oscillation of ultrasonic files, Endodontics Dental Traumatology, 6, pp. 12-15, (1990)
[2]  
Ahmad M, Pitt Ford TR, A comparison using macroradiography of canal shapes in teeth instrumented ultrasonically and by hand, Journal of Endodontics, 15, pp. 339-344, (1989)
[3]  
Ahmad M, Pitt Ford TR, Crum LA, Ultrasonic debridement of root canal: acoustic streaming and its possible role, Journal of Endodontics, 13, pp. 490-499, (1987)
[4]  
Ahmad M, Roy RA, Kamarudin AG, Safar M, The vibratory pattern of ultrasonic files driven piezoelectrically, International Endodontic Journal, 26, pp. 120-124, (1992)
[5]  
Barnett F, Trope M, Khoja M, Tronstad L, Bacterialogic status of root canal after sonic, ultrasonic and hand instrumentation, Endodontics and Dental Traumatolagy, 1, pp. 228-231, (1985)
[6]  
Briggs PFA, Gulabivala K, Stock CJR, Setchell D, The dentine removing characteristics of an ultrasonicaliy energized K‐file, International Endodontic Journal, 22, pp. 259-268, (1989)
[7]  
Craig WL, Messer HH, Eldeeb ME, The effect of varying the ultrasonic power setting on canal preparation, Journal of Endodontics, 16, pp. 273-278, (1990)
[8]  
Cunningham WT, Martin H, Forrest WR, Evaluation of root canal debridement by the endosonic synergistic system, Oral Surgery, 53, pp. 401-404, (1982)
[9]  
Cymerman JJ, Jerome LA, Moodnik RM, A scanning electron microscope study comparing, the efficacy of hand instrumentation with ultrasonic instrumentation of the root canal, Journal of Endodontics, 9, pp. 327-331, (1983)
[10]  
Lumley PJ, Walmsley AD, Inherent variability in the power output of endosonic instruments, International Endodontic Journal, 24, pp. 298-302, (1991)