PELVIC STRESSES INVITRO .1. MALSIZING OF ENDOPROSTHESES

被引:27
作者
FINLAY, JB
BOURNE, RB
LANDSBERG, RPD
ANDREAE, P
机构
[1] Univ of Western Ontario, London,, Ont, Can, Univ of Western Ontario, London, Ont, Can
关键词
BIOLOGICAL MATERIALS - Testing - PROSTHETICS - Design - STRAIN - Analysis;
D O I
10.1016/0021-9290(86)90194-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Seven embalmed human cadaveric hemi-pelves have been stripped of all soft tissues except the articular cartilage and instrumented with 25 strain-guage rosettes on both the medial and lateral surfaces. Loads up to 2. 5 kN were applied, without simulated muscle forces, to mimic the line-of-action of the resultant joint-force in a single-legged stance. In this parametric study, endoprostheses were studied at the 'correct' size and in sizes of 1 and 2 mm above and below the correct size. The correct size of endoprosthesis produced similar periacetabular stress data to those obtained with the normal femoral head; however, significant changes in stress on the medial and lateral aspects of the ilium suggested the correctly-sized spherical endoprosthesis had a different moment arm than its anatomical counterpart. Endoprostheses of 1 mm greater than the correct size caused major increases in the magnitude of both periacetabular and medial-wall stresses, while prosthes of plus 2 mm created dramatic and significant increases in magnitudes of these stresses. Endoprostheses smaller than the correct size caused only small but significant changes in the pattern of stresses up to plus 2 mm malsizing and, in particular, were associated with the disappearance of all periacetabular tensile stresses.
引用
收藏
页码:703 / 714
页数:12
相关论文
共 50 条
[11]   RELATIONS OF COMPRESSIVE PROPERTIES OF HUMAN CORTICAL BONE TO HISTOLOGICAL STRUCTURE AND CALCIFICATION [J].
EVANS, FG ;
VINCENTELLI, R .
JOURNAL OF BIOMECHANICS, 1974, 7 (01) :1-+
[12]   A TECHNIQUE FOR THE INVITRO MEASUREMENT OF PRINCIPAL STRAINS IN THE HUMAN TIBIA [J].
FINLAY, JB ;
BOURNE, RB ;
MCLEAN, J .
JOURNAL OF BIOMECHANICS, 1982, 15 (10) :723-739
[13]  
FISCHER LP, 1979, REV CHIR ORTHOP, V65, P47
[14]  
FISCHER LP, 1979, REV CHIR ORTHOP, V65, P121
[15]   STRESSES IN NORMAL PELVIS [J].
GOEL, VK ;
VALLIAPPAN, S ;
SVENSSON, NL .
COMPUTERS IN BIOLOGY AND MEDICINE, 1978, 8 (02) :91-104
[16]  
HARRIS WH, 1975, HIP, P93
[17]   THE DEVELOPMENT OF A TWO-DIMENSIONAL STRESS-OPTICAL MODEL OF THE OS COXAE [J].
HOLM, NJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :135-143
[18]   ON THE MODELING OF LONG BONES IN STRUCTURAL-ANALYSES [J].
HUISKES, R .
JOURNAL OF BIOMECHANICS, 1982, 15 (01) :65-69
[19]   MECHANICAL FUNCTION OF SUBCHONDRAL BONE AS EXPERIMENTALLY DETERMINED ON ACETABULUM OF HUMAN PELVIS [J].
JACOB, HAC ;
HUGGLER, AH ;
DIETSCHI, C ;
SCHREIBER, A .
JOURNAL OF BIOMECHANICS, 1976, 9 (10) :625-&
[20]  
LIONBERGER D, 1984, 30TH P ANN ORTH RES, P78