DUAL INJECTOR SOLVENT ELUTION AND FOCUSING TECHNIQUE FOR THE ONLINE ANALYSIS OF SOLID-PHASE EXTRACTION CARTRIDGES IN HPLC

被引:5
作者
RODIER, DR
BIRKS, JW
机构
[1] UNIV COLORADO,NOAA,COOPERAT INST RES ENVIRONM SCI,BOULDER,CO 80309
[2] UNIV COLORADO,DEPT CHEM & BIOCHEM,BOULDER,CO 80309
关键词
COLUMN LIQUID CHROMATOGRAPHY; SAMPLE PRECONCENTRATION; SOLID-PHASE EXTRACTION; SOLVENT FOCUSING; INJECTION TECHNIQUES;
D O I
10.1007/BF02320457
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new dual injector solvent focussing and elution technique developed for high-performance liquid chromatography (HPLC) greatly improves chromatographic efficiency for the on-line analysis of C18 solid-phase extraction (SPE) cartridges. Solutions containing three benzene homologs were used to characterize the dual injector analysis technique and to compare the chromatographic efficiency of this method with conventional SPE analysis methods. Sampling was performed off-line using a glass precolumn cartridge (3 mm i.d. x 30 mm) packed with 15-35 mum C18 silica. On-line cartridge analysis was achieved with two injection valves in either serial or parallel configuration. The injection loop of the first valve contains the eluting solvent, and the cartridge holder is connected in place of the injection loop of the second valve. When an injection is made, both valves are turned to the inject position, and the solvent plug is forced through the cartridge, focussing the analyte at the solvent front as it elutes the cartridge. Solvent focussing at the head of the column, resulting from preconditioning of the column with a small plug of water during injection, further minimizes the variance of the injection plug and improves the chromatographic efficiency. The technique has potential applications to environmental and biological fluid analysis where analyte preconcentration and resolution' from the sample matrix components may be difficult with current SPE methods.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 8 条
[1]  
GOEWIE CE, 1983, THESIS FREE U AMSTER
[2]  
HORACK J, 1993, LC GC-MAG SEP SCI, V11, P74
[3]  
NIELEN MWF, 1987, THESIS FREE U AMSTER
[4]   DETERMINATION OF CARBONYL-COMPOUNDS IN AIR BY HPLC USING ONLINE ANALYZED MICROCARTRIDGES, FLUORESCENCE AND CHEMILUMINESCENCE DETECTION [J].
NONDEK, L ;
MILOFSKY, RE ;
BIRKS, JW .
CHROMATOGRAPHIA, 1991, 32 (1-2) :33-39
[5]   MEASUREMENT OF SUB-PPBV CONCENTRATIONS OF ALDEHYDES IN A FOREST ATMOSPHERE USING A NEW HPLC TECHNIQUE [J].
NONDEK, L ;
RODLER, DR ;
BIRKS, JW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (06) :1174-1178
[6]  
POOLE CF, 1984, CONT PRACTICE CHROMA, P461
[7]  
RODIER DR, 1993, ENVIRON SCI TECHNOL, V27, P2814
[8]  
Sternberg J., 1966, ADV CHROMATOGR, P205