DUAL FUNCTIONALITIES OF 4-AMINODIPHENYLAMINE IN ENZYMATIC ASSAY AND MEDIATED BIOSENSOR CONSTRUCTION

被引:16
作者
GROOM, CA [1 ]
LUONG, JHT [1 ]
THATIPALMALA, R [1 ]
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL,PQ H4P 2R2,CANADA
关键词
D O I
10.1006/abio.1995.0069
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
4-Aminodiphenylamine (N-phenyl-1,4-phenylenediamine, CAS 101-54-2) and its water soluble HCl salt (CAS 2198-59-6) were demonstrated to be efficient mediators for glucose oxidase, lactate oxidase, xanthine oxidase, and lysine oxidase. Using cyclic voltammetry, single oxidative peak potentials were observed for scans ranging from 0 to 0.5 V vs Ag/AgCl. The half-wave potential for both preparations was O.11 V vs Ag/AgCl at pH 7 and decreased 59 mV per unit pH increase. Peak current data were analyzed to estimate diffusivities of 0.8 X 10(-5) cm(2)/s for soluble 4-ADPA HCl, and 2.36 X 10(-5) cm(2)/s for 4-ADPA solubilized in 2.5 mM 2-hydroxypropyl-beta-cyclodextrin. The overall second-order kinetic constants (k) for the reaction of reduced glucose oxidase with oxidized 4-ADPA HCl and 4-ADPA in cyclodextrin were estimated to be 1.8 X 10(5) and 1.7 x 10(5) M(-1) s(-1), respectively, using cyclic voltammetry measurements at varied scan rates and enzyme concentrations. Both preparations proved to be suitable electron accepters for horseradish peroxidase, as indicated by changes in absorbance spectra upon oxidation or reduction. The electrochemical and spectral behavior of the preparations were applied in conjunction with glucose oxidase to devise mediated amperometric and hydrogen peroxide-coupled spectrophotometric assays for glucose. The results of both assays compared favorably with the hexokinase reference method. (C) 1995 Academic Press, Inc.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 24 条
[1]   BIOELECTROCATALYSIS AND DIFFUSION KINETICS OF THE GLUCOSE-OXIDASE - GLUCOSE REACTION USING A WATER-SOLUBLE 1,1'-DIMETHYLFERROCENE-2-HYDROXYPROPYL-BETA-CYCLODEXTRIN COMPLEX [J].
BROWN, RS ;
LUONG, JHT .
ELECTROANALYSIS, 1994, 6 (5-6) :391-396
[2]  
CARAWAY WT, 1987, FUNDAMENTALS CLIN CH, P428
[3]  
CARR PW, 1980, IMMOBILIZED ENZYMES, P134
[4]   FERRICINIUM ION AS AN ELECTRON-ACCEPTOR FOR OXIDO-REDUCTASES [J].
CASS, AEG ;
DAVIS, G ;
GREEN, MJ ;
HILL, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 190 (1-2) :117-127
[5]  
CATTANEO M, 1995, IN PRESS ELECTROANAL
[6]   A STABLE WATER-SOLUBLE TETRAMETHYLBENZIDINE-2-HYDROXYPROPYL-BETA-CYCLODEXTRIN INCLUSION COMPLEX AND ITS APPLICATIONS IN ENZYME ASSAYS [J].
CATTANEO, MV ;
LUONG, JHT .
ANALYTICAL BIOCHEMISTRY, 1994, 223 (02) :313-320
[7]  
FEINLAND R, 1984, ENCY CHEM TECHNOLOGY, V12, P80
[8]  
Hill H.A., 1990, BIOSENSORS PRACTICAL, P19
[9]   CONCERNING THE TOXICITY OF 2 COMPOUNDS USED AS MEDIATORS IN BIOSENSOR DEVICES - 7,7,8,8-TETRACYANOQUINODIMETHANE (TCNQ) AND TETRATHIAFULVALENE (TTF) [J].
KULYS, J ;
SIMKEVICIENE, V ;
HIGGINS, IJ .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) :495-501
[10]   ENZYME ELECTRODE FOR THE DETERMINATION OF GLUCOSE [J].
LOBEL, E ;
RISHPON, J .
ANALYTICAL CHEMISTRY, 1981, 53 (01) :51-53