REMEASUREMENT AT HIGH RESOLVING POWER IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY

被引:13
作者
CAMPBELL, VL [1 ]
GUAN, ZQ [1 ]
LAUDE, DA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM & BIOCHEM,AUSTIN,TX 78712
关键词
D O I
10.1016/1044-0305(95)00230-B
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The Fourier transform ion cyclotron resonance mass spectrometry remeasurement experiment is demonstrated and evaluated under high resolution conditions. Signal-to-noise enhancement is observed for isotopically resolved bovine insulin peaks at a resolution of similar to 31,000 (full width at half height). The experiment is sensitive to space-charge effects and resultant changes in scan-to-scan signal-to-noise and resolution, Coulombic repulsion in the ion cloud during the high resolution remeasurement experiment can cause the cyclotron frequency to shift through the duration of the experiment, which results in broadened peak shapes when individual remeasurement spectra are coadded. By either reducing the number of ions in the cell or allowing the ion cloud to diffuse during the lifetime of the experiment, high resolution remeasurement spectra can be coadded without peak broadening or degradation of signal-to-noise ratio.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 26 条
[1]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[2]   CELL GEOMETRY CONSIDERATIONS FOR THE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY REMEASUREMENT EXPERIMENT [J].
CAMPBELL, VL ;
GUAN, ZQ ;
VARTANIAN, VH ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :420-425
[3]   SELECTIVE GENERATION OF CHARGE-DEPENDENT - INDEPENDENT ION ENERGY-DISTRIBUTIONS FROM A HEATED CAPILLARY ELECTROSPRAY SOURCE [J].
CAMPBELL, VL ;
GUAN, ZQ ;
LAUDE, DA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (04) :221-229
[4]  
CAMPBELL VL, 1993, 41ST P ASMS C MASS S, P443
[5]   FREQUENCY-SWEEP FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISARO.MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 26 (04) :489-490
[6]   FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CHEMICAL PHYSICS LETTERS, 1974, 25 (02) :282-283
[7]  
COMISAROW MB, 1982, ION CYCLOTRON RESONA, V2, P484
[8]   MAGNETRON MOTION OF IONS IN THE CUBICAL ICR CELL [J].
DUNBAR, RC ;
CHEN, JH ;
HAYS, JD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 57 (01) :39-56
[9]   BLOCH EQUATIONS APPLIED TO ION-CYCLOTRON RESONANCE SPECTROSCOPY - BROAD-BAND INTERCONVERSION BETWEEN MAGNETRON AND CYCLOTRON MOTION FOR ION AXIALIZATION [J].
GUAN, SH ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (06) :4486-4493
[10]   BROAD-BAND AXIALIZATION IN AN ION-CYCLOTRON RESONANCE ION-TRAP [J].
GUAN, SH ;
WAHL, MC ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1994, 100 (09) :6137-6140