2 ENZYME-LINKED IMMUNOSORBENT ASSAYS FOR DETECTING ANTIBODIES AGAINST MENINGOCOCCAL CAPSULAR POLYSACCHARIDE-A AND POLYSACCHARIDE-C

被引:9
作者
AKINWOLERE, O [1 ]
KUMARARATNE, DS [1 ]
BARTLETT, R [1 ]
GOODALL, DM [1 ]
CATTY, D [1 ]
机构
[1] UNIV BIRMINGHAM,SCH MED,DEPT INFECT,BIRMINGHAM B15 2TT,W MIDLANDS,ENGLAND
关键词
D O I
10.1136/jcp.47.5.405
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Aims-To evaluate two of the recent methods of coating microtitre plates in the enzyme linked immunosorbent assay (ELISA) for detecting human antibodies against meningococcal capsular polysaccharides A and C with a view to validating a specific meningococcal antibody assay for routine clinical use. Methods-Two four-layer ELISA protocols were standardised: one method utilised meningococcal polysaccharides conjugated to poly-L-lysine polypeptide for coating the microtitre plates; another used polysaccharides mixed with methylated human serum albumin (mHSA). Titration curves were plotted for the ELISAs and the squared Pearson correlation coefficient (R(2)) was used to determine the degree of accuracy of fit of the curves. Specificity tests were performed by inhibition and adsorption studies. Results-Both methods gave good titration curves with a high R(2) of >0.98, indicating a high degree of accuracy in forming the curves. The titration end point after vaccination, obtained by the mHSA method, was 20 times higher, however, than that obtained by the poly-L-lysine method. Specificity tests showed that in the ELISA using polysaccharide/poly-L-lysine antibody activity of a pre-vaccination serum sample was inhibited by 37%, and of post-vaccination serum by 50% with 1000-fold excess antigen. Antibody activity (post-vaccination) was reduced by 51% and 59%, respectively, by adsorption with antigen-coated Sepharose beads or adsorption with suspensions of killed meningococci. In contrast, antibody activity of a pre-vaccination serum was inhibited by 60% and a post-vaccination serum by 90% in ELISA employing polysaccharides mixed with mHSA. Reproducibility was better with the use of methylated human serum albumin than with poly-L-lysine; the former showed intrabatch and interbatch coefficients of variation of 4% and 2%, respectively, compared with 43% (intrabatch) and 16% (interbatch) obtained with the poly-L-lysine. Conclusion-It is concluded that the antibody assay using meningococcal polysaccharides groups A and C mixed with mHSA is much better than that using polysaccharides coupled with poly-L-lysine.
引用
收藏
页码:405 / 410
页数:6
相关论文
共 27 条
[21]  
MAKELA PH, 1975, LANCET, V2, P883
[22]   MODIFICATION OF A DIRECT ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR THE DETECTION OF IMMUNOGLOBULIN-G AND IMMUNOGLOBULIN-M ANTIBODIES TO PNEUMOCOCCAL CAPSULAR POLYSACCHARIDE [J].
MESSINA, JP ;
HICKOX, PG ;
LEPOW, ML ;
POLLARA, B ;
VENEZIA, RA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 21 (03) :390-394
[23]   The estimation of the bactericidal power of the blood [J].
Miles, AA ;
Misra, SS ;
Irwin, JO .
JOURNAL OF HYGIENE, 1938, 38 (06) :732-749
[24]   CONTROL OF EPIDEMIC MENINGOCOCCAL MENINGITIS BY MASS VACCINATION .2. PERSISTENCE OF ANTIBODY 4 YEARS AFTER VACCINATION [J].
MOHAMMED, I ;
ONYEMELUKWE, GC ;
OBINECHE, EN ;
GUPTA, N ;
OYEYINKA, GO .
JOURNAL OF INFECTION, 1984, 9 (02) :197-202
[25]  
ROBERTS R B, 1970, Journal of Experimental Medicine, V131, P499, DOI 10.1084/jem.131.3.499
[26]   LATEX AGGLUTINATION TEST FOR MEASUREMENT OF ANTIBODIES TO MENINGOCOCCAL POLYSACCHARIDES [J].
TRAMONT, EC ;
ARTENSTEIN, MS .
INFECTION AND IMMUNITY, 1972, 5 (03) :346-+
[27]   MEASUREMENT OF THE HUMORAL IMMUNE-RESPONSE AGAINST STREPTOCOCCUS-PNEUMONIAE TYPE-3 CAPSULAR POLYSACCHARIDE AND OLIGOSACCHARIDE CONTAINING ANTIGENS BY ELISA AND ELISPOT TECHNIQUES [J].
ZIGTERMAN, GJWJ ;
VERHEUL, AFM ;
ERNSTE, EBHW ;
ROMBOUTS, RFM ;
DEREUVER, MJ ;
JANSZE, M ;
SNIPPE, H ;
WILLERS, JMN .
JOURNAL OF IMMUNOLOGICAL METHODS, 1988, 106 (01) :101-107