EFFECT OF REGIONAL AND SYSTEMIC CHANGES IN VASOMOTOR TONE ON FINGER PRESSURE AMPLIFICATION

被引:36
作者
BOS, WJW [1 ]
VANDENMEIRACKER, AH [1 ]
WESSELING, KH [1 ]
SCHALEKAMP, MADH [1 ]
机构
[1] TNO, ACAD MED CTR, AMSTERDAM, NETHERLANDS
关键词
BRACHIAL ARTERY; BLOOD PRESSURE; DETERMINATION; FINGER; VASOCONSTRICTION; VASODILATATION; HEART RATE; PULSE;
D O I
10.1161/01.HYP.26.2.315
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Pulse wave amplification, which leads to increased peripheral systolic pressures, is observed during vasoconstriction after head-up tilt and during exercise. This may influence finger pressure measurements with the Finapres. To distinguish between changes in regional vascular tone and changes in systemic hemodynamics as a cause of pulse wave amplification, we measured finger pressure, intra-arterial brachial artery pressure, heart rate, and left ventricular ejection time during high-dose intravenous and low-dose intra-arterial infusions of phenylephrine and sodium nitroprusside in eight subjects. Forearm blood flow was measured by means of venous occlusion plethysmography. Intravenous phenylephrine at the highest dose caused an increase in mean brachial artery pressure of 24+/-3 mm Hg, a decrease in heart rate of 10+/-11 beats per minute, and an increase in ejection time of 23+/-9 milliseconds (all P<.01), whereas pulse wave amplification was reduced. Finapres underestimated the rise in systolic brachial artery pressure of 41+/-9 mm Hg by 11+/-12 mm Hg (P<.01). Forearm blood flow did not change. Intravenous nitroprusside caused a decrease in mean brachial artery pressure of 23+/-9 mm Hg, an increase in heart rate of 18+/-11 beats per minute, and a decrease in ejection time of 36+/-31 milliseconds (all P<.01), whereas pulse wave amplification increased. Finapres underestimated the fall in systolic brachial artery pressure of 30+/-13 mm Hg by 9+/-10 mm Hg (P<.05). Forearm blood flow did not change. During regional infusion of phenylephrine and nitroprusside forearm flow halved and doubled, respectively. Blood pressure levels and pulse wave amplification were not affected. One subject performed dynamic exercise, which caused an increase in blood pressure and heart rate and a decrease in ejection time. As previously observed during bicycle exercise and contrary to the results with phenylephrine, the rise in systolic brachial artery pressure was overestimated with Fi napres because of increased pulse wave amplification. We conclude that changes in regional vascular tone are not the main determinant of pulse wave amplification between the brachial and finger arteries. Changes in systemic hemodynamics, in particular changes in heart rate or ejection time, rather than changes in blood pressure level appear to be most important.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 22 条
  • [1] THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE
    BOS, WJW
    IMHOLZ, BPM
    VANGOUDOEVER, J
    WESSELING, KH
    VANMONTFRANS, GA
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (08) : 529 - 535
  • [2] DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS
    GARDNER, RM
    [J]. ANESTHESIOLOGY, 1981, 54 (03) : 227 - 236
  • [3] GIZDULICH P, 1990, 12TH P INT C IEEE EN, V12, P1046
  • [4] PHYSICAL-TRAINING AND BARORECEPTOR CONTROL OF SYMPATHETIC-NERVE ACTIVITY IN HUMANS
    GRASSI, G
    SERAVALLE, G
    CALHOUN, DA
    MANCIA, G
    [J]. HYPERTENSION, 1994, 23 (03) : 294 - 301
  • [5] MECHANISMS RESPONSIBLE FOR SYMPATHETIC ACTIVATION BY CIGARETTE-SMOKING IN HUMANS
    GRASSI, G
    SERAVALLE, G
    CALHOUN, DA
    BOLLA, GB
    GIANNATTASIO, C
    MARABINI, M
    DELBO, A
    MANCIA, G
    [J]. CIRCULATION, 1994, 90 (01) : 248 - 253
  • [6] COMPARISON OF FINAPRES NONINVASIVE BEAT-TO-BEAT FINGER BLOOD-PRESSURE WITH INTRABRACHIAL ARTERY PRESSURE DURING AND AFTER BICYCLE ERGOMETRY
    IDEMA, RN
    VANDENMEIRACKER, AH
    IMHOLZ, BPM
    TVELD, AJMI
    SETTELS, JJ
    VANECK, HJR
    SCHALEKAMP, MADH
    [J]. JOURNAL OF HYPERTENSION, 1989, 7 : S58 - S59
  • [7] IMHOLZ BPM, 1992, J HYPERTENS, V10, P979
  • [8] CONTINUOUS NON-INVASIVE BLOOD-PRESSURE MONITORING - RELIABILITY OF FINAPRES DEVICE DURING THE VALSALVA MANEUVER
    IMHOLZ, BPM
    VANMONTFRANS, GA
    SETTELS, JJ
    VANDERHOEVEN, GMA
    KAREMAKER, JM
    WIELING, W
    [J]. CARDIOVASCULAR RESEARCH, 1988, 22 (06) : 390 - 397
  • [9] NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT DURING ORTHOSTATIC STRESS COMPARED TO INTRAARTERIAL PRESSURE
    IMHOLZ, BPM
    SETTELS, JJ
    VANDERMEIRACKER, AH
    WESSELING, KH
    WIELING, W
    [J]. CARDIOVASCULAR RESEARCH, 1990, 24 (03) : 214 - 221
  • [10] COMPARISON OF SIMULTANEOUSLY RECORDED CENTRAL AND PERIPHERAL ARTERIAL PRESSURE PULSES DURING REST, EXERCISE AND TILTED POSITION IN MAN
    KROEKER, EJ
    WOOD, EH
    [J]. CIRCULATION RESEARCH, 1955, 3 (06) : 623 - 632