IMPROVED EJECTION FRACTION AND FLOW VELOCITY ESTIMATES WITH USE OF VIEW SHARING AND UNIFORM REPETITION TIME EXCITATION WITH FAST CARDIAC TECHNIQUES

被引:172
作者
FOO, TKF
BERNSTEIN, MA
AISEN, AM
HERNANDEZ, RJ
COLLICK, BD
BERNSTEIN, T
机构
[1] GE CO,MED SYST,COMP ENGN,WAUKESHA,WI 53188
[2] GE CO,MED SYST,ADV APPLICAT,WAUKESHA,WI 53188
[3] UNIV MICHIGAN,DEPT RADIOL,ANN ARBOR,MI 48109
关键词
HEART; VOLUME; MAGNETIC RESONANCE (MR); PHASE IMAGING; RAPID IMAGING; VOLUME MEASUREMENT;
D O I
10.1148/radiology.195.2.7724769
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To improve the accuracy of ventricular volume estimates and effective temporal resolution in fast cardiac acquisitions. MATERIALS AND METHODS: Data sets at intermediate temporal phases were generated by means of sharing of views from two temporally adjacent data sets. A simulated model was used, and studies with patients and volunteers were conducted. View sharing was implemented in both fast gradient-echo and fast phase-contrast cine acquisitions; breath holding was used when possible. RESULTS: Uniform repetition time (TR) radio-frequency (RF) excitation allowed a better assessment of the end-diastolic ventricular volume. In addition, view sharing provided a better estimate of end-systolic ventricular volume in cases in which rapid changes in volume occurred at or about the temporal boundary of the source images. View sharing also provided a much smoother representation of dynamic cardiac motion when viewed in a cine loop. CONCLUSION: View sharing and uniform TR RF excitation improve the accuracy of end-systolic and end-diastolic ventricular volume measurements by improving the effective temporal resolution.
引用
收藏
页码:471 / 478
页数:8
相关论文
共 13 条
  • [1] CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE
    ATKINSON, DJ
    EDELMAN, RR
    [J]. RADIOLOGY, 1991, 178 (02) : 357 - 360
  • [2] MINIMIZING TE IN MOMENT-NULLED OR FLOW-ENCODED 2-DIMENSIONAL AND 3-DIMENSIONAL GRADIENT-ECHO IMAGING
    BERNSTEIN, MA
    SHIMAKAWA, A
    PELC, NJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05): : 583 - 588
  • [3] BERNSTEIN MA, 1994, ANN M SOC MAGNETIC S, pS23
  • [4] PULMONARY VASCULATURE - SINGLE BREATH-HOLD MR IMAGING WITH PHASED-ARRAY COILS
    FOO, TKF
    MACFALL, JR
    HAYES, CE
    SOSTMAN, HD
    SLAYMAN, BE
    [J]. RADIOLOGY, 1992, 183 (02) : 473 - 477
  • [5] FOO TKF, 1993, 1993 P SOC MAGN RES, P1269
  • [6] VOLUME IMAGING WITH MR PHASED-ARRAYS
    HAYES, CE
    HATTES, N
    ROEMER, PB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 309 - 319
  • [7] THORACIC CARDIOVASCULAR ANOMALIES IN CHILDREN - EVALUATION WITH A FAST GRADIENT-RECALLED-ECHO SEQUENCE WITH CARDIAC-TRIGGERED SEGMENTED ACQUISITION
    HERNANDEZ, RJ
    AISEN, AM
    FOO, TKF
    BEEKMAN, RH
    [J]. RADIOLOGY, 1993, 188 (03) : 775 - 780
  • [8] LAUB G, 1993, 12TH P SMRM ANN M NE, P478
  • [9] ENCODING STRATEGIES FOR 3-DIRECTION PHASE-CONTRAST MR IMAGING OF FLOW
    PELC, NJ
    BERNSTEIN, MA
    SHIMAKAWA, A
    GLOVER, GH
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (04): : 405 - 413
  • [10] MR FLUOROSCOPY - TECHNICAL FEASIBILITY
    RIEDERER, SJ
    TASCIYAN, T
    FARZANEH, F
    LEE, JN
    WRIGHT, RC
    HERFKENS, RJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) : 1 - 15