CHARACTERIZATION OF REGENERATED SILK FIBROIN MEMBRANE FOR IMMOBILIZING PEROXIDASE AND CONSTRUCTION OF AN AMPEROMETRIC HYDROGEN-PEROXIDE SENSOR EMPLOYING PHENAZINE METHOSULFATE AS ELECTRON SHUTTLE

被引:51
作者
QIAN, JH
LIU, YC
LIU, HY
YU, TY
DENG, JQ
机构
[1] FUDAN UNIV,DEPT CHEM,SHANGHAI 200433,PEOPLES R CHINA
[2] FUDAN UNIV,DEPT MACROMOLEC SCI,SHANGHAI 200433,PEOPLES R CHINA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1995年 / 397卷 / 1-2期
基金
中国国家自然科学基金;
关键词
BIOSENSOR; HORSERADISH PEROXIDASE; HYDROGEN PEROXIDE; REGENERATED SILK FIBROIN; PHENAZINE METHOSULFATE;
D O I
10.1016/0022-0728(95)04158-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Regenerated silk fibroin prepared from waste silk was used for the first time as the immobilization matrix of peroxidase. The structures of the blend membranes of regenerated silk fibroin and peroxidase were investigated using IR and scanning electron microscopy. It was found that the two macromolecules were immiscible despite their intermolecular interactions. An amperometric H2O2 sensor using phenazine methosulphate as the electron transfer agent between horseradish peroxidase in a regenerated silk fibroin membrane and glassy carbon electrode was fabricated. The sensor was highly sensitive to H2O2 with a detection limit of 1.0 X 10(-7) M H2O2 and a response time of less than 5 s. The effect of the applied potential and the mediator concentration on the Michaelis-Menten constant was calculated, and the influence of various experimental parameters such as pH, temperature, applied potential and the mediator concentration was investigated for optimum analytical performance.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 19 条
  • [1] BENNETTO HP, 1987, INT ANAL, V8, P22
  • [2] TTF-MODIFIED BIOSENSORS FOR HYDROGEN-PEROXIDE
    BIFULCO, L
    CAMMAROTO, C
    NEWMAN, JD
    TURNER, APF
    [J]. ANALYTICAL LETTERS, 1994, 27 (08) : 1443 - 1452
  • [3] KOHLRABI-BASED AMPEROMETRIC BIOSENSOR FOR HYDROGEN-PEROXIDE MEASUREMENT
    CHEN, L
    LIN, MS
    HARA, M
    RECHNITZ, GA
    [J]. ANALYTICAL LETTERS, 1991, 24 (01) : 1 - 14
  • [4] Clark L C Jr, 1979, Methods Enzymol, V56, P448
  • [5] IMMOBILIZATION OF PEROXIDASE WITH A BOMBYX-MORI SILK FIBROIN MEMBRANE AND ITS APPLICATION TO BIOPHOTOSENSORS
    DEMURA, M
    ASAKURA, T
    NAKAMURA, E
    TAMURA, H
    [J]. JOURNAL OF BIOTECHNOLOGY, 1989, 10 (02) : 113 - 119
  • [6] A METHOD FOR ESTIMATION OF HYDROGEN-PEROXIDE BASED ON MEDIATED ELECTRON-TRANSFER REACTIONS OF PEROXIDASES AT ELECTRODES
    FREW, JE
    HARMER, MA
    HILL, HAO
    LIBOR, SI
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 201 (01): : 1 - 10
  • [7] MEDIATORLESS HORSERADISH-PEROXIDASE ENZYME ELECTRODES BASED ON ACTIVATED CARBON - POTENTIAL APPLICATION TO SPECIFIC BINDING ASSAY
    HO, WO
    ATHEY, D
    MCNEIL, CJ
    HAGER, HJ
    EVANS, GP
    MULLEN, WH
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 351 (1-2): : 185 - 197
  • [8] ACCURACY OF DETERMINATION OF HYDROGEN PEROXIDE BY CERATE OXIDIMETRY
    HURDIS, EC
    ROMEYN, H
    [J]. ANALYTICAL CHEMISTRY, 1954, 26 (02) : 320 - 325
  • [9] IMMOBILIZED ENZYME CHEMICALLY MODIFIED ELECTRODE AS AN AMPEROMETRIC SENSOR
    IANNIELLO, RM
    YACYNYCH, AM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (13) : 2090 - 2095
  • [10] AN ELECTROCHEMICAL SENSOR FOR HYDROGEN-PEROXIDE BASED ON PEROXIDASE ADSORBED ON A SPECTROGRAPHIC GRAPHITE ELECTRODE
    JONSSON, G
    GORTON, L
    [J]. ELECTROANALYSIS, 1989, 1 (05) : 465 - 468