CHARACTERIZATION OF REGENERATED SILK FIBROIN MEMBRANE FOR IMMOBILIZING PEROXIDASE AND CONSTRUCTION OF AN AMPEROMETRIC HYDROGEN-PEROXIDE SENSOR EMPLOYING PHENAZINE METHOSULFATE AS ELECTRON SHUTTLE

被引:51
作者
QIAN, JH
LIU, YC
LIU, HY
YU, TY
DENG, JQ
机构
[1] FUDAN UNIV,DEPT CHEM,SHANGHAI 200433,PEOPLES R CHINA
[2] FUDAN UNIV,DEPT MACROMOLEC SCI,SHANGHAI 200433,PEOPLES R CHINA
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1995年 / 397卷 / 1-2期
基金
中国国家自然科学基金;
关键词
BIOSENSOR; HORSERADISH PEROXIDASE; HYDROGEN PEROXIDE; REGENERATED SILK FIBROIN; PHENAZINE METHOSULFATE;
D O I
10.1016/0022-0728(95)04158-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Regenerated silk fibroin prepared from waste silk was used for the first time as the immobilization matrix of peroxidase. The structures of the blend membranes of regenerated silk fibroin and peroxidase were investigated using IR and scanning electron microscopy. It was found that the two macromolecules were immiscible despite their intermolecular interactions. An amperometric H2O2 sensor using phenazine methosulphate as the electron transfer agent between horseradish peroxidase in a regenerated silk fibroin membrane and glassy carbon electrode was fabricated. The sensor was highly sensitive to H2O2 with a detection limit of 1.0 X 10(-7) M H2O2 and a response time of less than 5 s. The effect of the applied potential and the mediator concentration on the Michaelis-Menten constant was calculated, and the influence of various experimental parameters such as pH, temperature, applied potential and the mediator concentration was investigated for optimum analytical performance.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 19 条
  • [11] ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER
    KAMIN, RA
    WILSON, GS
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (08) : 1198 - 1205
  • [12] OYYAMA N, 1985, ANAL CHEM, V57, P1526
  • [13] ENZYME-SUBSTRATE KINETICS OF ADSORBED CYTOCHROME-C PEROXIDASE ON PYROLYTIC-GRAPHITE ELECTRODES
    SCOTT, DL
    BOWDEN, EF
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (08) : 1217 - 1223
  • [14] THE ELECTROCATALYTIC ENZYME FUNCTION OF ADSORBED CYTOCHROME-C PEROXIDASE ON PYROLYTIC-GRAPHITE
    SCOTT, DL
    PADDOCK, RM
    BOWDEN, EF
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 341 (1-2): : 307 - 321
  • [15] METAL-DISPERSED CARBON PASTE ELECTRODES
    WANG, J
    NASER, N
    ANGNES, L
    WU, H
    CHEN, L
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (11) : 1285 - 1288
  • [16] BULK MODIFIED ENZYME ELECTRODES FOR REAGENTLESS DETECTION OF PEROXIDES
    WOLLENBERGER, U
    WANG, J
    OZSOZ, M
    GONZALEZROMERO, E
    SCHELLER, F
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 26 (02): : 287 - 296
  • [17] ENZYME ELECTRODES USING BIOELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE
    WOLLENBERGER, U
    BOGDANOVSKAYA, V
    BOBRIN, S
    SCHELLER, F
    TARASEVICH, M
    [J]. ANALYTICAL LETTERS, 1990, 23 (10) : 1795 - 1808
  • [18] Yaropolov AI, 1979, DOKL AKAD NAUK SSSR, V249, P1399
  • [19] DIRECT ELECTRON-TRANSFER AT HORSERADISH-PEROXIDASE COLLOIDAL GOLD MODIFIED ELECTRODES
    ZHAO, JG
    HENKENS, RW
    STONEHUERNER, J
    ODALY, JP
    CRUMBLISS, AL
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 327 (1-2) : 109 - 119