TRENDS IN THE COMBINATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROANALYTICAL METHODS

被引:4
作者
BUCHBERGER, W
机构
[1] Department of Analytical Chemistry, Johannes-Kepler-University, Linz
关键词
COLUMN LIQUID CHROMATOGRAPHY; ELECTROANALYTICAL METHODS;
D O I
10.1007/BF02269807
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent advances in the coupling of high-performance liquid chromatography with electrochemical detectors are discussed. Emphasis is laid on voltammetric detectors; new electrode materials and new excitation functions have lead to an enlarged field of applications, which hitherto were not accessible to the widely used oxidative amperometric detectors with carbon electrodes. Some non-inert metal electrodes and chemically modified electrodes are described in detail as well as pulsed amperometric detection and multiple electrode detectors. Various examples are given to illustrate the excellent selectivity of electrochemical detectors.
引用
收藏
页码:577 / 581
页数:5
相关论文
共 32 条
[11]   ION CHROMATOGRAPHY OF INORGANIC ANIONS WITH POTENTIOMETRIC DETECTION USING A METALLIC COPPER ELECTRODE [J].
HADDAD, PR ;
ALEXANDER, PW ;
TROJANOWICZ, M .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :363-374
[12]   ELECTROCATALYTIC AND ANALYTICAL RESPONSE OF COBALT PHTHALOCYANINE CONTAINING CARBON PASTE ELECTRODES TOWARD SULFHYDRYL COMPOUNDS [J].
HALBERT, MK ;
BALDWIN, RP .
ANALYTICAL CHEMISTRY, 1985, 57 (03) :591-595
[13]   POLYPYRROLE ELECTRODE AS A DETECTOR FOR ELECTROINACTIVE ANIONS BY FLOW-INJECTION ANALYSIS [J].
IKARIYAMA, Y ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1803-1806
[14]   POLYPYRROLE ELECTRODE AS A DETECTOR OF ANIONIC SUBSTANCES [J].
IKARIYAMA, Y ;
GALIATSATOS, C ;
HEINEMAN, WR ;
YAMAUCHI, S .
SENSORS AND ACTUATORS, 1987, 12 (04) :455-461
[15]   LIQUID-CHROMATOGRAPHY WITH PULSED ELECTROCHEMICAL DETECTION AT GOLD AND PLATINUM-ELECTRODES [J].
JOHNSON, DC ;
LACOURSE, WR .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :A589-A597
[16]  
KEMULA W, 1952, ROCZNIKI CHEM, V26, P281
[17]  
KISSINGER PT, 1973, ANAL LETT, V6, P465
[18]   DETERMINATION OF OXALIC-ACID IN BIOLOGICAL MATRICES BY LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION [J].
KOK, WT ;
GROENENDIJK, G ;
BRINKMAN, UAT ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1984, 315 (DEC) :271-278
[19]   AMPEROMETRIC DETECTION OF AMINO-ACIDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A COPPER ELECTRODE [J].
KOK, WT ;
BRINKMAN, UAT ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1983, 256 (01) :17-26
[20]  
MULLER SR, 1989, ANAL CHEM, V61, P2747