OPTIMAL RADIOGRAPHIC MAGNIFICATION FOR PORTAL IMAGING

被引:20
作者
BISSONNETTE, JP [1 ]
JAFFRAY, DA [1 ]
FENSTER, A [1 ]
MUNRO, P [1 ]
机构
[1] UNIV WESTERN ONTARIO, DEPT MED BIOPHYS, LONDON, ON, CANADA
关键词
D O I
10.1118/1.597189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two approaches to estimate the optimal radiographic magnification for a TV camera-based portal imaging system and portal films have been used. The first approach optimizes signal transfer while the second optimizes signal-to-noise ratio (SNR) transfer. In order to perform these optimization calculations, the physical characteristics of the imaging system (modulation transfer function and noise power spectrum) as well as the sizes of the radiation sources of our medical linear accelerators have been measured. Using these data, the optimal magnification considering signal transfer alone (M(signal)) has been calculated to range between 2.0 and 2.3 for the TV camera-based imaging system and is about 1.0 for portal films. Conversely, the optimal magnification considering SNR transfer (M(SNR)) has been calculated to range between 1.5 and 1.7 for the TV camera-based imaging system and is about 1.0 for portal films. The results suggest that most portal imaging systems are operated close to their optimal radiographic magnification.
引用
收藏
页码:1435 / 1445
页数:11
相关论文
共 49 条
  • [1] [Anonymous], 1976, 24 INT COMM RAD UN M
  • [2] DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    MCSHAN, DL
    MORTON, EJ
    YORKSTON, J
    LONGO, MJ
    STREET, RA
    [J]. MEDICAL PHYSICS, 1992, 19 (06) : 1455 - 1466
  • [3] BAILY NA, 1980, INT J RADIAT ONCOL, V6, P935, DOI 10.1016/0360-3016(80)90341-7
  • [4] BARRETT HH, 1981, RADIOLOGICAL IMAGING, V1, P137
  • [5] Bevington PR, 1969, DATA REDUCTION ERROR, P56
  • [6] A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS)
    BOYER, AL
    ANTONUK, L
    FENSTER, A
    VANHERK, M
    MEERTENS, H
    MUNRO, P
    REINSTEIN, LE
    WONG, J
    [J]. MEDICAL PHYSICS, 1992, 19 (01) : 1 - 16
  • [7] DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY
    BRAHME, A
    [J]. ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05): : 379 - 391
  • [8] WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS
    BYHARDT, RW
    COX, JD
    HORNBURG, A
    LIERMANN, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10): : 881 - 887
  • [9] A METHOD FOR MODULATION TRANSFER-FUNCTION DETERMINATION FROM EDGE PROFILES WITH CORRECTION FOR FINITE-ELEMENT DIFFERENTIATION
    CUNNINGHAM, IA
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1987, 14 (04) : 533 - 537
  • [10] CUNNINGHAM JR, 1982, PROGR MED PHYSICS, V1