OPTIMAL RADIOGRAPHIC MAGNIFICATION FOR PORTAL IMAGING

被引:20
作者
BISSONNETTE, JP [1 ]
JAFFRAY, DA [1 ]
FENSTER, A [1 ]
MUNRO, P [1 ]
机构
[1] UNIV WESTERN ONTARIO, DEPT MED BIOPHYS, LONDON, ON, CANADA
关键词
D O I
10.1118/1.597189
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two approaches to estimate the optimal radiographic magnification for a TV camera-based portal imaging system and portal films have been used. The first approach optimizes signal transfer while the second optimizes signal-to-noise ratio (SNR) transfer. In order to perform these optimization calculations, the physical characteristics of the imaging system (modulation transfer function and noise power spectrum) as well as the sizes of the radiation sources of our medical linear accelerators have been measured. Using these data, the optimal magnification considering signal transfer alone (M(signal)) has been calculated to range between 2.0 and 2.3 for the TV camera-based imaging system and is about 1.0 for portal films. Conversely, the optimal magnification considering SNR transfer (M(SNR)) has been calculated to range between 1.5 and 1.7 for the TV camera-based imaging system and is about 1.0 for portal films. The results suggest that most portal imaging systems are operated close to their optimal radiographic magnification.
引用
收藏
页码:1435 / 1445
页数:11
相关论文
共 49 条
  • [41] POTENTIAL FOR IMPROVEMENT IN RADIATION-THERAPY
    SUIT, HD
    BECHT, J
    LEONG, J
    STRACHER, M
    WOOD, WC
    VERHEY, L
    GOITEIN, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (04): : 777 - 786
  • [42] THE DESIGN OF MEGAVOLTAGE PROJECTION IMAGING-SYSTEMS - SOME THEORETICAL ASPECTS
    SWINDELL, W
    MORTON, EJ
    EVANS, PM
    LEWIS, DG
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 855 - 866
  • [43] A MATRIX IONIZATION-CHAMBER IMAGING DEVICE FOR ONLINE PATIENT SETUP VERIFICATION DURING RADIOTHERAPY
    VANHERK, M
    MEERTENS, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) : 369 - 378
  • [44] PERFORMANCE OF A PROTOTYPE FLUOROSCOPIC RADIOTHERAPY IMAGING-SYSTEM
    VISSER, AG
    HUIZENGA, H
    ALTHOF, VGM
    SWANENBURG, BN
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01): : 43 - 50
  • [45] Wagner R F, 1974, Med Phys, V1, P11, DOI 10.1118/1.1637272
  • [46] WHITE JE, 1982, CANCER, V50, P1084, DOI 10.1002/1097-0142(19820915)50:6<1084::AID-CNCR2820500611>3.0.CO
  • [47] 2-W
  • [48] ON METHODS OF INHOMOGENEITY CORRECTIONS FOR PHOTON TRANSPORT
    WONG, JW
    PURDY, JA
    [J]. MEDICAL PHYSICS, 1990, 17 (05) : 807 - 814
  • [49] ONLINE RADIOTHERAPY IMAGING WITH AN ARRAY OF FIBEROPTIC IMAGE REDUCERS
    WONG, JW
    BINNS, WR
    CHENG, AY
    GEER, LY
    EPSTEIN, JW
    KLARMANN, J
    PURDY, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1477 - 1484