THE REPRODUCIBILITY OF CD-109-BASED X-RAY-FLUORESCENCE MEASUREMENTS OF BONE LEAD

被引:43
作者
GORDON, CL [1 ]
WEBBER, CE [1 ]
CHETTLE, DR [1 ]
机构
[1] MCMASTER UNIV,DEPT PHYS & ASTRON,HAMILTON L8N 3Z5,ON,CANADA
关键词
BONE LEAD; REPRODUCIBILITY; X-RAY FLUORESCENCE;
D O I
10.2307/3432199
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We assessed the reproducibility of X-ray fluorescence-based lead measurements from multiple measurements made on a low-concentration plaster of paris phantom and in five subjects measured five times on two occasions. Over a 6-month period, 220 measurements of the same phantom were obtained and showed a standard deviation of 1.29 mu g Pb (g plaster of paris)(-1). The two sets of in vivo measurements were made 10 months apart and revealed a mean standard deviation of 3.4 mu g Pb (g bone mineral)(-1) and 5.1 mu g Pb (g bone mineral)(-1) for males and females, respectively. Our measured standard deviation exceeded by 20-30% the calculated standard deviation associated with a single measurement both in the phantom and in subjects. This indicates that some variance is introduced during the measurement process. Operator learning and consistency significantly minimized this increase variability. Measured lead concentrations of the left and right tibia in 14 subjects showed no significant differents between legs. As a results, either tibia can be sampled and compared over time. The levels of reproducibility we report here mean that X-ray fluorescence-based determinations of bone lead concentrations are reliable both over the short and long term. Thus, reasonably sized confidence intervals can be placed on detected changes in concentration and should permit acquisition of longitudinal data within a reasonable length of time.
引用
收藏
页码:690 / 694
页数:5
相关论文
共 19 条
[1]  
ARMSTRONG R, 1992, BRIT J IND MED, V49, P14
[2]  
CHETTLE DR, 1992, JUL NIEHS XRAY FLUOR
[3]  
CHRISTOFFERSSON JO, 1984, AM J IND MED, V6, P447, DOI 10.1002/ajim.4700060608
[4]  
ERKKILA J, 1992, BRIT J IND MED, V49, P631
[5]  
GERHARDSSON L, 1993, ARCH ENVIRON HEALTH, V48, P79
[6]  
GORDON CL, 1993, BRIT J IND MED, V50, P637
[7]  
GORDON CL, HUMAN BODY COMPOSITI, P285
[8]   X-RAY-FLUORESCENCE MEASUREMENTS OF LEAD BURDEN IN SUBJECTS WITH LOW-LEVEL COMMUNITY LEAD-EXPOSURE [J].
HU, H ;
MILDER, FL ;
BURGER, DE .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1990, 45 (06) :335-341
[9]  
LANDRIGAN PJ, 1989, BRIT J IND MED, V46, P593
[10]   AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS [J].
MARQUARDT, DW .
JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02) :431-441