COMPREHENSIVE 3-DIMNENSIONAL SEPARATION OF PEPTIDES USING SIZE-EXCLUSION CHROMATOGRAPHY REVERSED-PHASE LIQUID-CHROMATOGRAPHY OPTICALLY GATED CAPILLARY ZONE ELECTROPHORESIS

被引:156
作者
MOORE, AW [1 ]
JORGENSON, JW [1 ]
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
关键词
D O I
10.1021/ac00115a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multidimensional separation methods are attractive because of their potentially high peak capacities. Coupled-column systems in particular offer the advantages of online detection and automation. With the development of rapid two-dimensional (2D) analysis, it becomes possible to consider three-dimensional (3D) separation systems. In such a 3D system, effluent from a slow first dimension is repetitively sampled into a rapid 2D system. In the resultant data, each sample component has been subjected to three separative displacements, and the overall peak capacity is the product of that of each of the three dimensions. This paper demonstrates a comprehensive coupled-column 3D analysis of peptides. Size exclusion chromatography (SEC) is used as the first dimension to separate sample components by molecular weight, over an analysis time of several hours. The SEC effluent is repetitively sampled on-line into a rapid 2D reversed phase liquid chromatography/capillary zone electrophoresis (CZE) system with an analysis time of 7 min. Detection of sample zones is done only after the final CZE separation, by laser-induced fluorescence detection. Analysis data from this system consist of a series of 2D ''slices'' of the SEC effluent, which when stacked together give the 3D separation ''volume''.
引用
收藏
页码:3456 / 3463
页数:8
相关论文
共 9 条
[1]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[2]  
Giddings J. C., 1991, UNIFIED SEPARATION S
[3]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323
[4]  
GIDDINGS JC, 1990, MULTIDIMENSIONAL CHR, P1
[5]   PREPARATION AND EVALUATION OF PACKED CAPILLARY LIQUID-CHROMATOGRAPHY COLUMNS WITH INNER DIAMETERS FROM 20-MU-M TO 50-MU-M [J].
KENNEDY, RT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1128-1135
[6]  
LARMANN JP, 1993, THESIS U N CAROLINA
[7]   ON-COLUMN SAMPLE GATING FOR HIGH-SPEED CAPILLARY ZONE ELECTROPHORESIS [J].
MONNIG, CA ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :802-807
[8]   STUDY OF ZONE BROADENING IN OPTICALLY GATED HIGH-SPEED CAPILLARY ELECTROPHORESIS [J].
MOORE, AW ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3550-3560
[9]   THE COMPLETE AMINO-ACID-SEQUENCE OF HEN OVALBUMIN [J].
NISBET, AD ;
SAUNDRY, RH ;
MOIR, AJG ;
FOTHERGILL, LA ;
FOTHERGILL, JE .