COMPUTER-AIDED DIAGNOSIS FOR INTERSTITIAL INFILTRATES IN CHEST RADIOGRAPHS - OPTICAL-DENSITY DEPENDENCE OF TEXTURE MEASURES

被引:28
作者
MORISHITA, J [1 ]
DOI, K [1 ]
KATSURAGAWA, S [1 ]
MONNIERCHOLLEY, L [1 ]
MACMAHON, H [1 ]
机构
[1] UNIV CHICAGO, DEPT RADIOL, KURT ROSSMANN LABS RADIOL IMAGE RES, CHICAGO, IL 60637 USA
关键词
COMPUTER-AIDED DIAGNOSIS; INTERSTITIAL LUNG DISEASE; CHEST RADIOGRAPHY;
D O I
10.1118/1.597419
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have been developing a computerized scheme for automated detection and characterization of interstitial infiltrates based on the Fourier transform of lung texture. To improve the performance of the scheme, which was developed using digitized screen-film radiographs, optical-density dependence of both the gradient of the film used and the system noise associated with the laser scanner were investigated. Two hundred chest radiographs, including 100 abnormal cases with interstitial infiltrates, were digitized using a laser scanner. The root-mean-square (RMS) variations and the first moments of the power spectra, which correspond to the magnitude and coarseness of lung texture, were determined by Fourier transform of lung textures in numerous regions of interest (ROIs). The RMS variation was dependent upon the average optical density in the ROI, though no obvious trend existed for the first moment of the power spectrum. Dependence of the RMS variations on optical density was corrected for using the gradient curve of the film. Also, system noise associated with the laser scanner was corrected. Results indicated that the specificity was improved from 81% (without correction) to 89% (with corrections), without any loss of sensitivity (90%). Thus, the correspondence between the computer output and consensus interpretation of radiologists was improved with the new scheme compared to the previous one. This improved computerized scheme may be useful to radiologists in detecting interstitial infiltrates in chest radiographs.
引用
收藏
页码:1515 / 1522
页数:8
相关论文
共 24 条
[1]   COMPUTERIZED RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS - PRELIMINARY EVALUATION [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, MJ ;
JIA, H ;
DOI, K ;
DIXON, LB .
RADIOLOGY, 1993, 186 (02) :471-474
[2]   MULTIFRACTAL RADIOGRAPHIC ANALYSIS OF OSTEOPOROSIS [J].
CALIGIURI, P ;
GIGER, ML ;
FAVUS, M .
MEDICAL PHYSICS, 1994, 21 (04) :503-508
[3]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .1. AUTOMATED DETECTION OF MICROCALCIFICATIONS IN MAMMOGRAPHY [J].
CHAN, HP ;
DOI, K ;
GALHOTRA, S ;
VYBORNY, CJ ;
MACMAHON, H ;
JOKICH, PM .
MEDICAL PHYSICS, 1987, 14 (04) :538-548
[4]   IMPROVEMENT IN RADIOLOGISTS DETECTION OF CLUSTERED MICROCALCIFICATIONS ON MAMMOGRAMS - THE POTENTIAL OF COMPUTER-AIDED DIAGNOSIS [J].
CHAN, HP ;
DOI, K ;
VYBORNY, CJ ;
SCHMIDT, RA ;
METZ, CE ;
LAM, KL ;
OGURA, T ;
WU, YZ ;
MACMAHON, H .
INVESTIGATIVE RADIOLOGY, 1990, 25 (10) :1102-1110
[5]   AUTOMATED SELECTION OF REGIONS OF INTEREST FOR QUANTITATIVE-ANALYSIS OF LUNG TEXTURES IN DIGITAL CHEST RADIOGRAPHS [J].
CHEN, X ;
DOI, K ;
KATSURAGAWA, S ;
MACMAHON, H .
MEDICAL PHYSICS, 1993, 20 (04) :975-982
[6]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .2. COMPUTERIZED DETERMINATION OF VESSEL SIZES IN DIGITAL SUBTRACTION ANGIOGRAPHY [J].
FUJITA, H ;
DOI, K ;
FENCIL, LE ;
CHUA, KG .
MEDICAL PHYSICS, 1987, 14 (04) :549-556
[7]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .3. AUTOMATED DETECTION OF NODULES IN PERIPHERAL LUNG FIELDS [J].
GIGER, ML ;
DOI, K ;
MACMAHON, H .
MEDICAL PHYSICS, 1988, 15 (02) :158-166
[8]   DISAGREEMENTS IN CHEST ROENTGEN INTERPRETATION [J].
HERMAN, PG ;
GERSON, DE ;
HESSEL, SJ ;
MAYER, BS ;
WATNICK, M ;
BLESSER, B ;
OZONOFF, D .
CHEST, 1975, 68 (03) :278-282
[9]  
HOFFMANN KR, 1986, SPIE MED 14, V626, P326
[10]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY - EFFECT OF DIGITAL PARAMETERS ON THE ACCURACY OF COMPUTERIZED ANALYSIS OF INTERSTITIAL DISEASE IN DIGITAL CHEST RADIOGRAPHS [J].
KATSURAGAWA, S ;
DOI, K ;
NAKAMORI, N ;
MACMAHON, H .
MEDICAL PHYSICS, 1990, 17 (01) :72-78