SPIN LOCK MAGNETIC-RESONANCE-IMAGING IN THE DIFFERENTIATION OF HEPATIC HEMANGIOMAS AND METASTASES

被引:18
作者
HALAVAARA, JT
LAMMINEN, AE
BONDESTAM, S
SEPPONEN, RE
TANTTU, JI
机构
[1] UNIV HELSINKI,CENT HOSP,DEPT RADIOL,SF-00290 HELSINKI,FINLAND
[2] HELSINKI UNIV TECHNOL,FAC ELECT ENGN,SF-02150 ESPOO,FINLAND
[3] PICKER NORDSTAR INC,SF-00510 HELSINKI,FINLAND
关键词
D O I
10.1259/0007-1285-68-815-1198
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spin lock (SL) imaging technique, generating T-1 rho-weighted images, was applied to the differentiation of hepatic haemangiomas from metastatic focal liver lesions. 17 haemangiomas and 16 metastases in 32 patients were imaged at the field-strength of 0.1 T using a multiple slice SL technique and a conventional gradient-echo (GRE) sequence with identical timing parametres. Spin lock effects of the hepatic lesions and different abdominal tissues were calculated. Images with adequate coverage of the liver and of good quality with few motion induced artefacts were acquired. A definite, statistically significant, difference was found between the SL-effects of hepatic haemangiomas and liver metastases. Haemangiomas showed an SL effect of 46.6 +/- 3.4% and metastases of 56.2 +/- 5.8% (mean +/- SD, p < 0.0001). The multiple slice SL technique showed potential in distinguishing haemangiomas from metastatic liver lesions and should be considered as an alternative to the conventional T,and magnetization transfer (MT) based methods.
引用
收藏
页码:1198 / 1203
页数:6
相关论文
共 26 条
[11]   MAGNETIC-FIELD DEPENDENCE OF 1/T1 OF PROTONS IN TISSUE [J].
KOENIG, SH ;
BROWN, RD ;
ADAMS, D ;
EMERSON, D ;
HARRISON, CG .
INVESTIGATIVE RADIOLOGY, 1984, 19 (02) :76-81
[12]   T(1P) DISPERSION IMAGING OF DISEASED MUSCLE-TISSUE [J].
LAMMINEN, AE ;
TANTTU, JI ;
SEPPONEN, RE ;
PIHKO, H ;
KORHOLA, OA .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (789) :783-787
[13]   HEPATIC HEMANGIOMAS AND MALIGNANT-TUMORS - IMPROVED DIFFERENTIATION WITH HEAVILY T2-WEIGHTED CONVENTIONAL SPIN-ECHO MR-IMAGING [J].
MCFARLAND, EG ;
MAYOSMITH, WW ;
SAINI, S ;
HAHN, PF ;
GOLDBERG, MA ;
LEE, MJ .
RADIOLOGY, 1994, 193 (01) :43-47
[14]  
MCGOWAN JC, 1994, JMRI-J MAGN RESON IM, V4, P79
[15]   HEPATIC METASTASES AND CAVERNOUS HEMANGIOMAS - DISTINCTION WITH STANDARD-DOSE AND TRIPLE-DOSE GADOTERIDOL-ENHANCED MR-IMAGING [J].
MITCHELL, DG ;
SAINI, S ;
WEINREB, J ;
DELANGE, EE ;
RUNGE, VM ;
KUHLMAN, JE ;
PARISKY, Y ;
JOHNSON, CD ;
BROWN, JJ ;
SCHNALL, M ;
HERFKENS, RJ ;
DAVIS, PL ;
GORCZYCA, D ;
SICA, G ;
FOSTER, GS ;
BERNARDINO, ME .
RADIOLOGY, 1994, 193 (01) :49-57
[16]  
OHTOMO K, 1985, RADIOLOGY, V198, P421
[17]   MAGNETIZATION TRANSFER OF HEPATIC-LESIONS - EVALUATION OF A NOVEL CONTRAST TECHNIQUE IN THE ABDOMEN [J].
OUTWATER, E ;
SCHNALL, MD ;
BRAITMAN, LE ;
DINSMORE, BJ ;
KRESSEL, HY .
RADIOLOGY, 1992, 182 (02) :535-540
[18]   LIVER METASTASIS DETECTION - COMPARATIVE SENSITIVITIES OF MR IMAGING AND CT SCANNING [J].
REINIG, JW ;
DWYER, AJ ;
MILLER, DL ;
WHITE, M ;
FRANK, JA ;
SUGARBAKER, PH ;
CHANG, AE ;
DOPPMAN, JL .
RADIOLOGY, 1987, 162 (01) :43-47
[19]   SPIN LOCKING FOR MAGNETIC-RESONANCE IMAGING WITH APPLICATION TO HUMAN-BREAST [J].
SANTYR, GE ;
HENKELMAN, RM ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (01) :25-37
[20]  
SEPPONEN RE, 1993, SOC MAGN RES MED NEW, P1218