ULTRASOUND MEASUREMENTS ON THE OS CALCIS IN A PROSPECTIVE MULTICENTER STUDY

被引:52
作者
HANS, D
SCHOTT, AM
CHAPUY, MC
BENAMAR, M
KOTZKI, PD
CORMIER, C
POUILLES, JM
MEUNIER, PJ
机构
[1] EPIDOS CTR, AMIENS, FRANCE
[2] EPIDOS CTR, MONTPELLIER, FRANCE
[3] EPIDOS CTR, PARIS, FRANCE
[4] EPIDOS CTR, TOULOUSE, FRANCE
关键词
BROAD-BAND ULTRASOUND ATTENUATION; SPEED-OF-SOUND; STIFFNESS INDEX; INTERUNIT PRECISION;
D O I
10.1007/BF00297182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ultrasonic assessment is a new approach to assess both quality and density. Two ultrasonic parameters are measured on the os calcis: the attenuation or broadband ultrasound attenuation (BUA) and the velocity or speed of sound (SOS). The interunit variations in vitro and in vivo of an ultrasound instrument, the Lunar Achilles(R) system, used in a French multicenter study named EPIDOS, were calculated and the stability of these intruments over a 12-month period was evaluated. A third parameter called ''stiffness index,'' calculated from the SOS and BUA, was also used in this study. The average CV in vitro for the BUA and SOS was 0.92% and 0.12%, respectively, and the average CV in vivo for the BUA, the SOS, and the stiffness index was 1.83%, 0.23%, and 1.9%, respectively. The interunit (or inter-machines) variations were calculated by a one-way analysis of variance. We detected small but significant measurement differences among centers on a phantom for both SOS (maximum significant difference 0.4%) and stiffness (maximum significant difference 3.5%) but not for BUA. Similar differences were found in vivo. The precision over 12 months of the interunit variations in vitro was evaluated by measuring a single phantom traveling from one center to another several times. The range of the CV for the BUA (1.54- 0.51%), for the SOS (0.25-0.14%), and for the stiffness index (2.26-1.10%) are explained in part by technical failures. The variation among the five Achilles was estimated by the combined CV which was 1.42% for the BUA, 0.32% for the SOS, and 2.33% for the stiffness index. In conclusion, our findings indicate that equipment from one manufacturer appears to be consistent between machines for the BUA, but not completely for the SOS. The results for this stiffness index are necessarily influenced by both SOS and BUA. The shortterm and long-term interunit precision is good, both in vitro and in vivo. Such results provide increased confidence in multicenter clinical trials where ultrasonic data are pooled.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 21 条
  • [1] ULTRASOUND ATTENUATION OF THE OS CALCIS IN WOMEN WITH OSTEOPOROSIS AND HIP-FRACTURES
    BARAN, DT
    KELLY, AM
    KARELLAS, A
    GIONET, M
    PRICE, M
    LEAHEY, D
    STEUTERMAN, S
    MCSHERRY, B
    ROCHE, J
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (03) : 138 - 142
  • [2] BLAKE GM, 1993, COMP PERFORMANCE COM, V3
  • [3] BRANDENBURGER G, 1992, J BONE MINER RES S, V7, P368
  • [4] ULTRASOUND ATTENUATION OF THE CALCANEUS IN THE FEMALE-POPULATION - NORMATIVE DATA
    DAMILAKIS, JE
    DRETAKIS, E
    GOURTSOYIANNIS, NC
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (03) : 180 - 183
  • [5] Hans D, 1993, Eur J Med, V2, P157
  • [6] MEASUREMENTS OF POSTMENOPAUSAL BONE LOSS WITH A NEW CONTACT ULTRASOUND SYSTEM
    HERD, RJM
    BLAKE, GM
    RAMALINGAM, T
    MILLER, CG
    RYAN, PJ
    FOGELMAN, I
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1993, 53 (03) : 153 - 157
  • [7] KAUFMAN JJ, 1993, J BONE MINER RES, V8, P517
  • [8] INFLUENCE OF FAT ON ULTRASOUND MEASUREMENTS OF THE OS CALCIS
    KOTZKI, PO
    BUYCK, D
    HANS, D
    THOMAS, E
    BONNEL, F
    FAVIER, F
    MEUNIER, PJ
    ROSSI, M
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) : 91 - 95
  • [9] Langton C M, 1984, Eng Med, V13, P89, DOI 10.1243/EMED_JOUR_1984_013_022_02
  • [10] PRELIMINARY EVALUATION OF A NEW ULTRASOUND BONE DENSITOMETER
    LEES, B
    STEVENSON, JC
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1993, 53 (03) : 149 - 152