CLINICAL USE OF ONLINE PORTAL IMAGING FOR DAILY PATIENT TREATMENT VERIFICATION

被引:65
作者
HERMAN, MG
ABRAMS, RA
MAYER, RR
机构
[1] Division of Radiation Oncology, The Johns Hopkins Oncology Center, Baltimore, MD 21287-8922
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 28卷 / 04期
关键词
ONLINE IMAGING; RADIOTHERAPY; PORTAL IMAGING; LOCALIZATION;
D O I
10.1016/0360-3016(94)90123-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the ease of use by clinical staff and reliability of an electronic portal imaging system and evaluate the potential to utilize on-line imaging to assess accuracy of daily patient treatment positioning in radiation therapy. Methods and Materials: A computer controlled fluorescent screen-mirror imaging system was used to acquire on-line Portal images. A physician panel assessed on-line image quality relative to standard portal film. Clinical use of the imager was implemented through a protocol where images were obtained during the first six monitor units of external beam. The images were visually compared to a reference portal and patient setup was adjusted for errors exceeding 5 mm. Subsequent off-line analysis was utilized to give insight into the magnitude of clinical setup error in the visually accepted images. Results: Physician evaluation of on-line image quality with an initial 211 images found that 70% were comparable or superior to standard film portal images. Eighty percent of treatment fields fit completely within the on-line imaging area. Eight percent of on-line images were rejected due to poor image quality. Twelve percent of the daily treatment setups imaged required adjustment overall, but specific field types predictably required more frequent adjustment (pelvic and mantle fields). Off-line analysis of accepted images demonstrates that 18% of the final images had setup errors exceeding 5 mm. Conclusion: On-line imaging facilitated daily portal alignment and verification. Ease of use, almost instantaneous viewing and consistent ability to identify and locate anatomical landmarks imply the potential for on-line imaging to replace film based approaches. Retrospective analysis of daily images reveals that visual assessment of setup is not sufficient for eliminating localization errors. Further improvement is required with respect to detecting localization error and fully encompassing larger field sizes.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 33 条
[1]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[2]  
BALTER JM, 1992, MED PHYS, V19, P802
[3]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[4]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[5]  
EZZ A, 1991, INT J RADIAT ONCOL, V22, P159
[6]   IMMOBILIZATION ERROR - SOME THEORETICAL CONSIDERATIONS [J].
GOITEIN, M ;
BUSSE, J .
RADIOLOGY, 1975, 117 (02) :407-412
[7]   A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM [J].
GRAHAM, ML ;
CHENG, AY ;
GEER, LY ;
BINNS, WR ;
VANNIER, MW ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :613-619
[8]   SUPRAGLOTTIC LARYNGEAL CARCINOMA - AN ANALYSIS OF DOSE-TIME-VOLUME FACTORS IN 410 PATIENTS [J].
HARWOOD, AR ;
BEALE, FA ;
CUMMINGS, BJ ;
KEANE, TJ ;
PAYNE, DG ;
RIDER, WD ;
RAWLINSON, E ;
ELHAKIM, T .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (03) :311-319
[9]   ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY [J].
HUIZENGA, H ;
LEVENDAG, PC ;
DEPORRE, PMZR ;
VISSER, AG .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) :181-187
[10]   LOCALIZATION ERRORS IN MANTLE-FIELD IRRADIATION FOR HODGKINS-DISEASE [J].
HULSHOF, M ;
VANUYTSEL, L ;
VANDENBOGAERT, W ;
VANDERSCHUEREN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (03) :679-683