OXYGEN-CONSUMPTION OF THE LIVING HUMAN BRAIN MEASURED AFTER A SINGLE INHALATION OF POSITRON EMITTING OXYGEN

被引:117
作者
OHTA, S [1 ]
MEYER, E [1 ]
THOMPSON, CJ [1 ]
GJEDDE, A [1 ]
机构
[1] MONTREAL NEUROL HOSP & INST,MCCONNELL BRAIN IMAGING CTR,POSITRON IMAGING LABS,MONTREAL H3A 2B4,QUEBEC,CANADA
关键词
POSITRON EMISSION TOMOGRAPHY; OXYGEN CONSUMPTION; UNIDIRECTIONAL CLEARANCE OF OXYGEN; SINGLE OXYGEN STUDY; TIME-WEIGHTED INTEGRATION METHOD;
D O I
10.1038/jcbfm.1992.28
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We measured the rate of washout of O-15-labeled water generated from labeled oxygen accumulated in brain after bolus [O-15]O2 inhalation, and compared the washout with that of labeled water measured with H-2 O-15. Contrary to the original expectation, the radioactive water generated from labeled oxygen failed to leave the brain tissue at the rate predicted by exogenous water. Therefore, the use of a separately measured value for exogenous water clearance led to an error in the calculation of oxygen consumption. A new method presented in this paper eliminated the error by yielding oxygen consumption in a single oxygen study. We used time-weighted integration to estimate three parameters, including the unidirectional clearance from blood to brain (K1O2), the fractional clearance of the distribution volume in brain (k2O2), and the vascular volume correction (V(o)). We showed that the clearance of oxygen from blood to brain can be estimated with acceptable precision by this new approach, and that the new method yields a reliable measure of oxygen consumption.
引用
收藏
页码:179 / 192
页数:14
相关论文
共 33 条
  • [1] STRATEGY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW USING SHORT-LIVED TRACERS AND EMISSION TOMOGRAPHY
    ALPERT, NM
    ERIKSSON, L
    CHANG, JY
    BERGSTROM, M
    LITTON, JE
    CORREIA, JA
    BOHM, C
    ACKERMAN, RH
    TAVERAS, JM
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (01) : 28 - 34
  • [2] DETERMINATION OF OBJECT CONTOUR FROM PROJECTIONS FOR ATTENUATION CORRECTION IN CRANIAL POSITRON EMISSION TOMOGRAPHY
    BERGSTROM, M
    LITTON, J
    ERIKSSON, L
    BOHM, C
    BLOMQVIST, G
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) : 365 - 372
  • [3] WEIGHTED INTEGRATION METHOD FOR LOCAL CEREBRAL BLOOD-FLOW MEASUREMENTS WITH POSITRON EMISSION TOMOGRAPHY
    CARSON, RE
    HUANG, SC
    GREEN, MV
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (02) : 245 - 258
  • [4] HYDROPEROXIDE METABOLISM IN MAMMALIAN ORGANS
    CHANCE, B
    SIES, H
    BOVERIS, A
    [J]. PHYSIOLOGICAL REVIEWS, 1979, 59 (03) : 527 - 605
  • [5] PERFORMANCE FIGURES AND IMAGES FROM THE THERASCAN-3128 POSITRON EMISSION TOMOGRAPH
    COOKE, BE
    EVANS, AC
    FANTHOME, EO
    ALARIE, R
    SENDYK, AM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 640 - 644
  • [6] ANALYSIS OF SOME ERRORS IN THE MEASUREMENT OF OXYGEN EXTRACTION AND OXYGEN-CONSUMPTION BY THE EQUILIBRIUM INHALATION METHOD
    CORREIA, JA
    ALPERT, NM
    BUXTON, RB
    ACKERMAN, RH
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1985, 5 (04) : 591 - 599
  • [7] EFFECT OF VASCULAR ACTIVITY IN THE DETERMINATION OF RATE CONSTANTS FOR THE UPTAKE OF F-18 LABELED 2-FLUORO-2-DEOXY-D-GLUCOSE - ERROR ANALYSIS AND NORMAL VALUES IN OLDER SUBJECTS
    EVANS, AC
    DIKSIC, M
    YAMAMOTO, YL
    KATO, A
    DAGHER, A
    REDIES, C
    HAKIM, A
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (06) : 724 - 738
  • [8] Fennema M, 1989, Adv Exp Med Biol, V248, P451
  • [9] QUANTITATIVE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN-METABOLISM IN MAN USING O-15 AND POSITRON EMISSION TOMOGRAPHY - THEORY, PROCEDURE, AND NORMAL VALUES
    FRACKOWIAK, RSJ
    LENZI, GL
    JONES, T
    HEATHER, JD
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) : 727 - 736
  • [10] FRIEDMAN PA, 1972, J BIOL CHEM, V247, P173