TRACE-LEVEL ANALYSIS OF VOLATILE AND SEMIVOLATILE ORGANIC-COMPOUNDS IN WATER USING A MEMBRANE/JET SEPARATOR INTERFACED TO AN ION-TRAP MASS-SPECTROMETER

被引:32
作者
WONG, PSH [1 ]
COOKS, RG [1 ]
机构
[1] PURDUE UNIV,DEPT CHEM,W LAFAYETTE,IN 47907
关键词
MASS SPECTROMETRY; TRACE ANALYSIS; MEMBRANE JET SEPARATOR;
D O I
10.1016/0003-2670(95)00143-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion trap mass spectrometer, equipped with a membrane/jet separator interface, is used for the direct detection of volatile and semi-volatile organic compounds in aqueous solutions. Aqueous sample is passed through a capillary membrane, the outside surface of which is continuously purged by helium. The permeate is pneumatically transported to the mass spectrometer via a jet separator which acts as an additional enrichment device. The performance and response characteristics of non-porous silicone and microporous polytetrafluoroethylene (PTFE) membranes are studied. The microporous membrane allows sufficient water to pass for it to be used as a reagent gas for chemical ionization. Both types of membranes provide detection limits in the parts per trillion (pptr) to parts per billion (ppb) range with a linear dynamic range of 3 orders of magnitude for some volatile organic compounds. Results show that there is no detectable matrix effect on response in the selected cases examined. The use of microporous membranes to analyze more polar compounds, such as 5-hydroxymethyl furfuraldehyde and lactic acid, is also demonstrated. The effects of other experimental parameters, such as membrane temperature and length, on sensitivity are also investigated.
引用
收藏
页码:387 / 398
页数:12
相关论文
共 34 条
[1]  
BAUER SJ, 1993, TALANTA, V40, P103
[2]  
BAUER SJ, IN PRESS ANAL CHEM
[3]   MEMBRANE INTERFACE FOR SELECTIVE INTRODUCTION OF VOLATILE COMPOUNDS DIRECTLY INTO THE IONIZATION-CHAMBER OF A MASS-SPECTROMETER [J].
BIER, ME ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :597-601
[4]   DIRECT INSERTION MEMBRANE PROBE FOR SELECTIVE INTRODUCTION OF ORGANIC-COMPOUNDS INTO A MASS-SPECTROMETER [J].
BIER, ME ;
KOTIAHO, T ;
COOKS, RG .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :175-190
[5]   INVIVO MASS-SPECTROMETRIC DETERMINATION OF ORGANIC-COMPOUNDS IN BLOOD WITH A MEMBRANE PROBE [J].
BRODBELT, JS ;
COOKS, RG ;
TOU, JC ;
KALLOS, GJ ;
DRYZGA, MD .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :454-458
[6]  
CISPER ME, 1994, 42ND P ASMS C MASS S
[7]  
COOKS RG, 1992, ACS SYM SER, V508, P126
[8]   JET SEPARATOR MEMBRANE INTRODUCTION MASS-SPECTROMETRY FOR ONLINE QUANTITATION OF VOLATILE ORGANIC-COMPOUNDS IN AQUEOUS-SOLUTIONS [J].
DEJARME, LE ;
BAUER, SJ ;
COOKS, RG ;
LAURITSEN, FR ;
KOTIAHO, T ;
GRAF, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) :935-942
[9]   MASS-SPECTROMETRIC EVIDENCE FOR THE FORMATION OF BROMOCHLORAMINE AND N-BROMO-N-CHLOROMETHYLAMINE IN AQUEOUS-SOLUTION [J].
GAZDA, M ;
DEJARME, LE ;
CHOUDHURY, TK ;
COOKS, RG ;
MARGERUM, DW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (03) :557-561
[10]  
GONZALO ER, 1992, ANAL CHIM ACTA, V259, P37