ULTRA-TRACE ANALYSIS OF PHENOLS IN WATER USING HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE REACTION DETECTION

被引:26
作者
LAMPRECHT, G [1 ]
HUBER, JFK [1 ]
机构
[1] UNIV VIENNA,INST ANALYT CHEM,A-1090 VIENNA,AUSTRIA
关键词
D O I
10.1016/0021-9673(94)89050-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ultra-sensitive HPLC method for the determination of phenols in water based on flow-through reaction is described. The phenols are concentrated by a two-step liquid-liquid extraction with dichloromethane and after evaporation of the organic solvent the separation is carried out on an octadecyl-silica column by a gradient of water-acetonitrile. Detection is performed by an on-fine twin detection system. First dinitrophenols are detected by UV-absorption measurement followed by oxidation of phenols with cerium(IV) in a tubular how-through reactor and fluorescence measurement of cerium(III). Detection limits in the lower ppt range can be achieved. The influence of reaction time, temperature and reagent concentration on reaction yield was investigated. Identification and quantitation is improved by use of internal standards. The method was applied to samples of surface and drinking water.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 46 条
[1]   DETERMINATION OF PRIORITY POLLUTANT PHENOLS BY ISOCRATIC HPLC [J].
ALARCON, P ;
BUSTOS, A ;
CANAS, B ;
ANDRES, MD ;
POLO, LM .
CHROMATOGRAPHIA, 1987, 24 :613-616
[2]   RETENTION OF PHENOLS ON AN OCTADECYL-BONDED VINYLALCOHOL COPOLYMER GEL [J].
ARAI, Y ;
HIRUKAWA, M ;
HANAI, T .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (04) :635-642
[3]   TRACE DETERMINATION OF PHENOLIC-COMPOUNDS IN WATER BY REVERSED PHASE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION USING A CARBON-POLYETHYLENE TUBULAR ANODE [J].
ARMENTROUT, DN ;
MCLEAN, JD ;
LONG, MW .
ANALYTICAL CHEMISTRY, 1979, 51 (07) :1039-1045
[4]   REVERSED-PHASE LIQUID-CHROMATOGRAPHIC SEPARATION OF PHENOLIC-COMPOUNDS WITH A NEW DERIVATIZING REACTION [J].
BAIOCCHI, C ;
CAMPI, E ;
GENNARO, M ;
MENTASTI, E ;
MIRTI, P .
CHROMATOGRAPHIA, 1982, 15 (10) :660-664
[5]   HPLC IDENTIFICATION AND SEPARATION OF PHENOLIC-COMPOUNDS DIAZOTIZED WITH SULFANILIC ACID - STRUCTURAL EFFECTS ON RETENTION TIMES [J].
BAIOCCHI, C ;
GENNARO, MC ;
CAMPI, E ;
MENTASTI, E ;
ARUGA, R .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1982, 15 (19) :1539-1548
[6]   DETERMINATION OF PHENOLS BY HPLC DOWN TO PPT LEVELS [J].
BALDWIN, DA ;
DEBOWSKI, JK .
CHROMATOGRAPHIA, 1988, 26 :186-190
[7]   DETERMINATION OF PHENOLS IN WATER AND WASTE-WATER BY POSTCOLUMN REACTION DETECTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BIGLEY, FP ;
GROB, RL .
JOURNAL OF CHROMATOGRAPHY, 1985, 350 (02) :407-416
[8]   DETERMINATION OF PHENOLS IN WATER SAMPLES AS 4-AMINOANTIPYRINE DERIVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BLO, G ;
DONDI, F ;
BETTI, A ;
BIGHI, C .
JOURNAL OF CHROMATOGRAPHY, 1983, 257 (01) :69-79
[9]  
BLO G, 1985, J CHROMATOGR, V295, P231
[10]  
BROWN FR, 1989, J CHROMATOGR, V479, P441