摘要
Objective: Our goal was to evaluate contrast-enhanced MRI using an endorectal coil in detecting and staging prostate carcinoma. Materials and Methods: Sixty patients with clinically suspected prostate carcinoma were examined by T1-weighted contrast-enhanced endorectal coil MRI at 1.5 T. Results were compared with T2-weighted images in all cases and with histologic findings following radical prostatectomy in 28 patients. Results: Prostate carcinomas showed no consistent pattern of contrast enhancement. In 27 patients, the tumor enhanced less than the surrounding prostatic tissue; in 10 patients, enhancement was heterogeneous; and in 23 cases, the lesion was hyperintense compared with normal glandular tissue. With respect to tumor delineation, contrast-enhanced sequences were superior to T2-weighted images in 1 case only; in 24 patients, the tumor could not be delineated at all. However, contrast-enhanced sequences provided a higher diagnostic confidence in delineating the seminal vesicles, prostate capsule, and neurovascular bundle in nine, six, and three cases, respectively. In the operated patients, accuracy, sensitivity, and specificity for staging advanced disease were comparable for both sequences. Conclusion: The T2-weighted sequences remain mandatory for delineation of prostate carcinoma. Contrast-enhanced T1-weighted sequences do not improve overall staging accuracy and therefore are not warranted routinely, but should be considered in cases requiring clearer delineation of the prostate capsule and/or seminal vesicles.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 14 条
  • [1] USE OF ENDORECTAL SURFACE COIL MAGNETIC-RESONANCE-IMAGING FOR LOCAL STAGING OF PROSTATE-CANCER
    CHELSKY, MJ
    SCHNALL, MD
    SEIDMON, EJ
    POLLACK, HM
    [J]. JOURNAL OF UROLOGY, 1993, 150 (02) : 391 - 395
  • [2] Gevenois P A, 1992, J Belge Radiol, V75, P5
  • [3] LEVI F, 1993, SOZ PRAVENTIVMED, V3, P155
  • [4] EVALUATION OF THE PROSTATE AND PROSTATIC-CARCINOMA WITH GADOLINIUM-ENHANCED ENDORECTAL COIL MR IMAGING
    MIROWITZ, SA
    BROWN, JJ
    HEIKEN, JP
    [J]. RADIOLOGY, 1993, 186 (01) : 153 - 157
  • [5] THE PELVIS - T2-WEIGHTED FAST SPIN-ECHO MR-IMAGING
    NGHIEM, HV
    HERFKENS, RJ
    FRANCIS, IR
    SOMMER, FG
    JEFFREY, RB
    LI, KCP
    STEINER, RM
    GLOVER, GH
    [J]. RADIOLOGY, 1992, 185 (01) : 213 - 217
  • [6] TOLERANCE DATA OF GD-DTPA - A REVIEW
    NIENDORF, HP
    DINGER, JC
    HAUSTEIN, J
    CORNELIUS, I
    ALHASSAN, A
    CLAUSS, W
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1991, 13 (01) : 15 - 20
  • [7] SAFETY OF GADOLINIUM-DTPA - EXTENDED CLINICAL-EXPERIENCE
    NIENDORF, HP
    HAUSTEIN, J
    CORNELIUS, I
    ALHASSAN, A
    CLAUSS, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) : 222 - 228
  • [8] MR-IMAGING OF PROSTATE-CANCER WITH AN ENDORECTAL SURFACE COIL TECHNIQUE - CORRELATION WITH WHOLE-MOUNT SPECIMENS
    QUINN, SF
    FRANZINI, DA
    DEMLOW, TA
    ROSENCRANTZ, DR
    KIM, JH
    HANNA, RM
    SZUMOWSKI, J
    [J]. RADIOLOGY, 1994, 190 (02) : 323 - 327
  • [9] CURRENT ROLE OF MR-IMAGING IN THE STAGING OF ADENOCARCINOMA OF THE PROSTATE
    SCHIEBLER, ML
    SCHNALL, MD
    POLLACK, HM
    LENKINSKI, RE
    TOMASZEWSKI, JE
    WEIN, AJ
    WHITTINGTON, R
    RAUSCHNING, W
    KRESSEL, HY
    [J]. RADIOLOGY, 1993, 189 (02) : 339 - 352
  • [10] A LOOK AT THE YEAR AND DECADE AHEAD
    SCHNAARS, SP
    [J]. INTERNATIONAL JOURNAL OF FORECASTING, 1990, 6 (01) : 1 - 2