A METHOD FOR IN-VIVO HIGH-RESOLUTION MRI OF RAT SPINAL-CORD INJURY

被引:50
作者
FORD, JC [1 ]
HACKNEY, DB [1 ]
JOSEPH, PM [1 ]
PHELAN, M [1 ]
ALSOP, DC [1 ]
TABOR, SL [1 ]
HAND, CM [1 ]
MARKOWITZ, RS [1 ]
BLACK, P [1 ]
机构
[1] HAHNEMANN UNIV,DEPT NEUROSURG,PHILADELPHIA,PA 19102
关键词
SPINAL CORD INJURY; HIGH RESOLUTION MRI; RADIOFREQUENCY COILS;
D O I
10.1002/mrm.1910310216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed an implanted radiofrequency coil to obtain high resolution in vivo MR images at 1.9 Tesla of rat spinal cords that have been injured using a standardized weight drop technique. The signal-to-noise ratio and motion artifact suppression of these images is superior to that achieved in earlier attempts at this field strength using an external surface coil. The high quality and spatial resolution provided by this technique afford the possibility for longitudinal studies of experimental spinal cord injury before and after treatment, as well as detailed correlation of in vivo MRI contrast, histopathological findings, and functional deficit, in a controlled setting.
引用
收藏
页码:218 / 223
页数:6
相关论文
共 15 条
  • [1] SURFACE COIL IMAGING OF RAT SPINE AT 7.0-T
    BANSON, ML
    COFER, GP
    HEDLUND, LW
    JOHNSON, GA
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (06) : 929 - 934
  • [2] MODELS OF SPINAL-CORD INJURY .3. DYNAMIC LOAD TECHNIQUE
    BLACK, P
    MARKOWITZ, RS
    DAMJANOV, I
    FINKELSTEIN, SD
    KUSHNER, H
    GILLESPIE, J
    FELDMAN, M
    [J]. NEUROSURGERY, 1988, 22 (01) : 51 - 60
  • [3] MORPHOMETRIC ANALYSIS OF EXPERIMENTAL SPINAL-CORD INJURY IN THE CAT - THE RELATION OF INJURY INTENSITY TO SURVIVAL OF MYELINATED AXONS
    BLIGHT, AR
    DECRESCITO, V
    [J]. NEUROSCIENCE, 1986, 19 (01) : 321 - +
  • [4] CHEN CN, 1989, BIOMEDICAL MAGNETIC, P160
  • [5] IMPLANTED COIL MR MICROSCOPY OF RENAL PATHOLOGY
    FARMER, THR
    JOHNSON, GA
    COFER, GP
    MARONPOT, RR
    DIXON, D
    HEDLUND, LW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (03) : 310 - 323
  • [6] ACUTE CERVICAL-SPINE TRAUMA - CORRELATION OF MR IMAGING FINDINGS WITH DEGREE OF NEUROLOGIC DEFICIT
    FLANDERS, AE
    SCHAEFER, DM
    DOAN, HT
    MISHKIN, MM
    GONZALEZ, CF
    NORTHRUP, BE
    [J]. RADIOLOGY, 1990, 177 (01) : 25 - 33
  • [7] FORD JC, 1989, 37 ANN M ASS U RAD S, P60
  • [8] HEMORRHAGE AND EDEMA IN ACUTE SPINAL-CORD COMPRESSION - DEMONSTRATION BY MR IMAGING
    HACKNEY, DB
    ASATO, R
    JOSEPH, PM
    CARVLIN, MJ
    MCGRATH, JT
    GROSSMAN, RI
    KASSAB, EA
    DESIMONE, D
    [J]. RADIOLOGY, 1986, 161 (02) : 387 - 390
  • [9] INSITU MAGNETIC-RESONANCE MICROSCOPY
    HOLLETT, MD
    COFER, GP
    JOHNSON, GA
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (12) : 965 - 968
  • [10] INDUCTIVE COUPLING AND TUNING IN NMR PROBES - APPLICATIONS
    KUHNS, PL
    LIZAK, MJ
    LEE, SH
    CONRADI, MS
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01): : 69 - 76