CLASSIFICATION OF RESIDENTIAL EXPOSURE TO NITROGEN-DIOXIDE

被引:11
作者
LAMBERT, WE
SAMET, JM
STIDLEY, CA
SPENGLER, JD
机构
[1] UNIV NEW MEXICO,MED CTR,DEPT MED,ALBUQUERQUE,NM 87131
[2] HARVARD UNIV,SCH PUBL HLTH,DEPT ENVIRONM SCI & PHYSIOL,BOSTON,MA 02115
来源
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS | 1992年 / 26卷 / 12期
关键词
EXPOSURE MISCLASSIFICATION; NITROGEN DIOXIDE; PASSIVE SAMPLERS;
D O I
10.1016/0960-1686(92)90407-C
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In epidemiological studies of indoor nitrogen dioxide (NO2) reported to date, only a limited number of measurements were made to estimate personal exposures. The accuracy of exposure estimates depends on the measurement error inherent in the samplers and in the sampling scheme. If categorical measures of exposure are used, the consequences of measurement error vary with classification rules. The effects of alternative measurement strategies on exposure classification were evaluated using NO2 diffusion sampler measurements from 653 residences with gas cooking ranges. A time-series of consecutive 2-week integrated measurements was obtained for each home. During the winter season, the standard deviation was 26% of the mean. The probability of misclassification, a function of the mean and the standard deviation per home, was examined for three concentration classes (< 25, 25-50, greater-than-or-equal-to 50 ppb). The average probability of misclassification was 10% for three 2-week integrated measurements across the winter and decreased to under 5% for continuous sampling (i.e. 13 consecutive 2-week samples). The sensitivity and predictive value were improved by increasing the number of samples obtained. The misclassification is determined by the number of concentration classes and by the relationship of class boundaries to the distribution of true means.
引用
收藏
页码:2185 / 2192
页数:8
相关论文
共 17 条
[11]   PERSONAL SAMPLER FOR NITROGEN-DIOXIDE [J].
PALMES, ED ;
GUNNISON, AF ;
DIMATTIO, J ;
TOMCZYK, C .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1976, 37 (10) :570-577
[12]  
Samet J.M., 1987, AM REV RESPIR DIS, V138, P1496
[13]   A STUDY OF RESPIRATORY ILLNESSES IN INFANTS AND NITROGEN-DIOXIDE EXPOSURE [J].
SAMET, JM ;
LAMBERT, WE ;
SKIPPER, BJ ;
CUSHING, AH ;
MCLAREN, LC ;
SCHWAB, M ;
SPENGLER, JD .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1992, 47 (01) :57-63
[14]  
SHY CM, 1978, B NEW YORK ACAD MED, V54, P1155
[15]   NITROGEN-DIOXIDE INSIDE AND OUTSIDE 137 HOMES AND IMPLICATIONS FOR AMBIENT AIR-QUALITY STANDARDS AND HEALTH-EFFECTS RESEARCH [J].
SPENGLER, JD ;
DUFFY, CP ;
LETZ, R ;
TIBBITTS, TW ;
FERRIS, BG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1983, 17 (03) :164-168
[16]  
1985, SAS USERS GUIDE
[17]  
1985, COMMITTEE EPIDEMIOLO