USE OF FLOW INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE DETERMINATION OF NIOBIUM, VANADIUM, AND TITANIUM IN MICROALLOYED STEELS

被引:8
作者
COEDO, AG
DORADO, MT
机构
[1] Centro Nacional de Investigaciones, Metalurgicas (CSIC), Madrid
关键词
FLOW INJECTION; INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY; MICROALLOYED STEELS; NIOBIUM; VANADIUM; AND TITANIUM DETERMINATION;
D O I
10.1366/0003702953963364
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of microsampling flow injection inductively coupled plasma-mass spectrometry for the determination of Nh, V, and Ti in microalloyed steels samples is described. A microwave nitric acid digestion procedure, resulting in 0.4% m/v Fe [approximate to 1.75% m/v (NO3)(3)Fe] test solutions, was used for sample dissolution. The flow injection parameters, such as carrier flow rate and sample loop volume, were optimized with respect to sensitivity and stability. Yttrium, with an ionization potential close to that of the analytes considered, and with a close mass number, was used as internal standard. The obtained detection limits, in mu g of analyte per gram of steel, were 0.010 for Nb, 0.017 for Ti, and 0.025 for V. The RSD values, at concentration levels of more than 10 times the detection limit, were less than 1.5%. Three certified reference materials, from the National Institute of Standards and Technology (Gaithersburg, MD)-NIST 2165, 2166, and 2167-were analyzed, from 0.4% m/v steel sample solutions, with 1% v/v HNO3 multielement calibration solutions. The close agreement with the certified values demonstrates the accuracy of the method developed.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 17 条
[1]  
ANDERSON STG, 1993, APPL PLASMA SOURCE M, V2, P72
[2]  
COEDO AG, 1994, J ANAL ATOM SPECTROM, V9, P111
[3]   CHARACTERISTICS OF FLOW-INJECTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR TRACE-METAL ANALYSIS [J].
DEAN, JR ;
EBDON, L ;
CREWS, HM ;
MASSEY, RC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (02) :349-354
[4]  
DENOYER ER, 1993, ATOM SPECTROSC, V14, P162
[5]  
DENOYER ER, 1994, ATOM SPECTROSC, V15, P7
[6]  
GRAY JM, 1990, ADV MATER PROCESS, V1, P17
[7]  
JARVIS KE, 1992, HDB INDUCTIVELY COUP, P119
[8]  
LUCK J, 1989, FRESENIUZ Z ANAL CHE, V331, P129
[9]   DETECTION LIMITS VERSUS MATRIX EFFECTS - ANALYSIS OF SOLUTIONS WITH HIGH AMOUNTS OF DISSOLVED SOLIDS BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
RICHNER, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) :927-931
[10]   ANALYSIS OF SAMPLES CONTAINING LARGE AMOUNTS OF DISSOLVED SOLIDS USING MICROSAMPLING FLOW-INJECTION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
STROH, A ;
VOLLKOPF, U ;
DENOYER, ER .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (08) :1201-1205