MAXIMAL PHYSICAL WORK PERFORMANCE WITH EUROPEAN STANDARD BASED FIRE-PROTECTIVE CLOTHING SYSTEM AND EQUIPMENT IN RELATION TO INDIVIDUAL CHARACTERISTICS

被引:60
作者
LOUHEVAARA, V
ILMARINEN, R
GRIEFAHN, B
KUNEMUND, C
MAKINEN, H
机构
[1] FINNISH INST OCCUPAT HLTH,DEPT PHYS,SF-01620 VANTAA,FINLAND
[2] UNIV DORTMUND,INST ARBEITSPHYSIOL,D-44139 DORTMUND 1,GERMANY
来源
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY | 1995年 / 71卷 / 2-3期
关键词
WORK PHYSIOLOGY; FIRE FIGHTING; PERSONAL PROTECTIVE EQUIPMENT; CARDIORESPIRATORY WORK CAPACITY; ANTHROPOMETRICS; POWER OUTPUT;
D O I
10.1007/BF00854982
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Every fire fighter needs to wear fire-protective clothing and a self-contained breathing apparatus (SCBA) several times a year while carrying out various fire-fighting and rescue operations in hazardous work environments. The aim of the present study was to quantify the effects of a multilayer turnout suit designed to fulfil European standard EN 469 used over standardized (Nordic) clothing and with SCBA (total mass 25.9 kg) on maximal physical work performance, and to evaluate the relationship between individual characteristics and power output with the fire-protective clothing system and SCBA. The subjects were 12 healthy firemen aged 26-46 years. The range of their body mass, body fat and maximal oxygen consumption was 69-101 kg, 10-20% and 2.70-5.86 1 . min(-1), respectively. The maximal tests without (control) and with the fire-protective clothing system and SCBA were carried out on a treadmill in a thermoneutral environment. When compared to the control test, the decrease in the maximal power output in terms of maximal working time and walking speed averaged 25% (P < 0.001) varying from 18% to 34% with the fire-protective clothing system and SCBA. At maximum, no significant differences were found in pulmonary ventilation, absolute oxygen consumption, the respiratory exchange ratio, heart rate, systolic blood pressure, the rate-pressure product, mechanical efficiency, and the rating of perceived exertion between the tests with and without the fire-protective clothing system and SCBA. The reduction of the power output was related to the extra mass of the fire protective clothing and SCBA. In this study, robust build and parameters associated with good anaerobic capacity were the most powerful individual characteristics contributing to the smallest drop in the power output with the fire-protective clothing system and SCBA. All possible means to decrease the mass of both the fire-protective clothing system and SCBA for maintaining the sufficient power output in physically demanding fire-fighting and rescue tasks need to be considered.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 22 条
[1]  
BORG G, 1970, Scandinavian Journal of Rehabilitation Medicine, V2, P92
[2]   INFLUENCE OF HEAVY WEIGHT CARRYING ON CARDIORESPIRATORY SYSTEM DURING EXERCISE [J].
BORGHOLS, EAM ;
DRESEN, MHW ;
HOLLANDER, AP .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1978, 38 (03) :161-169
[3]   MEDICAL EVALUATION OF FIRE FIGHTERS - HOW FIT ARE THEY FOR DUTY [J].
DAVIS, PO ;
BIERSNER, RJ ;
BARNARD, RJ ;
SCHAMADAN, J .
POSTGRADUATE MEDICINE, 1982, 72 (02) :241-&
[4]   ASSESSMENT OF AMOUNT OF FAT IN HUMAN BODY FROM MEASUREMENTS OF SKINFOLD THICKNESS [J].
DURNIN, JVG ;
RAHAMAN, MM .
BRITISH JOURNAL OF NUTRITION, 1967, 21 (03) :681-+
[5]  
ILMARINEN R, 1993, 33 JAHR TAG DTSCH GE, P259
[6]  
Ilmarinen R., 1994, 6 INT CON ENVIR ERGO, P78
[7]  
ILMARINEN R, 1992, 5TH P INT C ENV ERG, P90
[8]   EFFECTS OF INDUSTRIAL RESPIRATORS ON BREATHING PATTERN AT DIFFERENT WORK LEVELS [J].
LOUHEVAARA, V ;
SMOLANDER, J ;
KORHONEN, O ;
TUOMI, T .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1986, 55 (02) :142-146
[9]  
LOUHEVAARA V, 1985, J OCCUP ENVIRON MED, V27, P213
[10]   MAXIMAL WORKING TIMES WITH A SELF-CONTAINED BREATHING APPARATUS [J].
LOUHEVAARA, V ;
SMOLANDER, J ;
KORHONEN, O ;
TUOMI, T .
ERGONOMICS, 1986, 29 (01) :77-85