MAGNETIC-RESONANCE ANGIOGRAPHY OF THE CENTRAL CHEST VEINS - A NEW GOLD STANDARD

被引:52
作者
HARTNELL, GG [1 ]
HUGHES, LA [1 ]
FINN, JP [1 ]
LONGMAID, HE [1 ]
机构
[1] DEACONESS HOSP,DEPT RADIOL SCI,BOSTON,MA
关键词
MAGNETIC RESONANCE (MR); ANGIOGRAPHY; COMPARATIVE STUDIES; VASCULAR STUDIES; SUPERIOR VENA CAVA; THORAX; MRI; THROMBOSIS; VEINS; THORACIC;
D O I
10.1378/chest.107.4.1053
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The systemic chest veins may be difficult to show comprehensively by contrast venography, especially if there is limited venous access or contraindications to intravenous contrast. As an alternative, can magnetic resonance angiography (MRA) reliably detect occluded chest veins and predict suitable sites for central venous access? Patients and methods: Eighty-four patients were examined using breath-hold time-of-flight MRA and three-dimensional image reconstruction, Thirty-three were evaluated to identify possible central venous access. Fifty-seven patients were examined to diagnose and stage central venous occlusion. Results: The associated diagnoses were malignancy 46, parenteral nutrition 21, hemodialysis 6, chemotherapy 4, and other long-term venous access 7. Of the 28 patients in whom MRA predicted a patent site for central venous access, satisfactory access was achieved. In two patients, cannulation of veins shown to be occluded on MRA was attempted unsuccessfully. Correlation with contrast venography was available in 17. There was agreement with MRA concerning the level of occluded veins in all cases, Contrast venography did not show all patent veins, including some accessed during surgical line placement, Conclusion: Compared with surgical line placement or contrast venography, MRA of the systemic chest veins is accurate. Patent and occluded chest veins are reliably defined, including potential sites for central line placement, in a way that is not possible with other techniques. MRA may be the new ''gold standard'' for defining systemic venous anatomy in the chest.
引用
收藏
页码:1053 / 1057
页数:5
相关论文
共 13 条
  • [1] DIGITAL SUBTRACTION VENOGRAPHY IN CENTRAL VENOUS OBSTRUCTION
    BENENATI, JF
    BECKER, GJ
    MAIL, JT
    HOLDEN, RW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (04) : 685 - 688
  • [2] ELSTER AD, 1993, RADIOLOGY, V186, P1
  • [3] SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING
    FELMLEE, JP
    EHMAN, RL
    [J]. RADIOLOGY, 1987, 164 (02) : 559 - 564
  • [4] FINN J P, 1992, Magnetic Resonance Quarterly, V8, P1
  • [5] CENTRAL VENOUS OCCLUSION - MR ANGIOGRAPHY
    FINN, JP
    ZISK, JHS
    EDELMAN, RR
    WALLNER, BK
    HARTNELL, GG
    STOKES, KR
    LONGMAID, HE
    [J]. RADIOLOGY, 1993, 187 (01) : 245 - 251
  • [6] RAPID NMR IMAGING OF DYNAMIC PROCESSES USING THE FLASH TECHNIQUE
    FRAHM, J
    HAASE, A
    MATTHAEI, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) : 321 - 327
  • [7] LIMITATIONS OF MAGNETIC-RESONANCE-IMAGING AND ULTRASOUND-DIRECTED (DUPLEX) SCANNING IN THE DIAGNOSIS OF SUBCLAVIAN VEIN-THROMBOSIS
    HAIRE, WD
    LYNCH, TG
    LUND, GB
    LIEBERMAN, RP
    EDNEY, JA
    [J]. JOURNAL OF VASCULAR SURGERY, 1991, 13 (03) : 391 - 397
  • [8] MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING
    LAUB, GA
    KAISER, WA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) : 377 - 382
  • [9] 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY - APPLICATIONS IN THE ABDOMEN AND THORAX
    LEWIN, JS
    LAUB, G
    HAUSMANN, R
    [J]. RADIOLOGY, 1991, 179 (01) : 261 - 264
  • [10] RAPTOPOULOS V, 1986, CRIT REV DIAGN IMAG, V25, P373