CELL-DAMAGE IN-VITRO FOLLOWING DIRECT-CONTACT WITH FINE PARTICLES OF TITANIUM, TITANIUM-ALLOY AND COBALT-CHROME-MOLYBDENUM ALLOY

被引:70
作者
EVANS, EJ
机构
[1] Department of Anatomy, University of Wales College of Cardiff, Cardiff, CF1 3YF
基金
英国惠康基金;
关键词
BIOCOMPATIBILITY; FIBROBLASTS; ORTHOPEDIC IMPLANTS; WEAR DEBRIS;
D O I
10.1016/0142-9612(94)90170-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fibroblastic cells in vitro were exposed to powders of titanium, titanium-aluminium-vanadium alloy and cobalt-chrome-molybdenum (Co-Cr-Mo) alloy, either in direct contact with the cells or separated from the cells by a microporous membrane. Fine particles of all the materials reduced cell growth when in direct contact with cells, but only the finest particles of Co-Cr-Mo alloy caused cell damage through the microporous membrane. This provides further evidence that there is a mechanism of cell damage in vitro which depends on a direct interaction between cells and particles and is largely independent of the chemical nature of the particle.
引用
收藏
页码:713 / 717
页数:5
相关论文
共 11 条
[1]  
DARBY AJ, 1990, IMPLANT BONE INTERFA, P51
[2]  
EVANS E J, 1991, Clinical Materials, V7, P241, DOI 10.1016/0267-6605(91)90065-N
[3]   THE INVITRO TOXICITY OF COBALT-CHROME-MOLYBDENUM ALLOY AND ITS CONSTITUENT METALS [J].
EVANS, EJ ;
THOMAS, IT .
BIOMATERIALS, 1986, 7 (01) :25-29
[4]   TOXICITY OF HYDROXYAPATITE INVITRO - THE EFFECT OF PARTICLE-SIZE [J].
EVANS, EJ .
BIOMATERIALS, 1991, 12 (06) :574-576
[5]   THE EFFECT OF GRINDING CONDITIONS ON THE TOXICITY OF COBALT CHROME MOLYBDENUM PARTICLES INVITRO [J].
EVANS, EJ ;
BENJAMIN, M .
BIOMATERIALS, 1987, 8 (05) :377-384
[6]   THE BIOLOGIC EFFECTS OF IMPLANT MATERIALS [J].
GALANTE, JO ;
LEMONS, J ;
SPECTOR, M ;
WILSON, PD ;
WRIGHT, TM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :760-775
[7]  
HOWIE DW, 1988, CLIN ORTHOP RELAT R, V232, P244
[8]   STUDY ON EFFECTS OF PARTICULATE METALS OF ORTHOPEDIC INTEREST ON MURINE MACROPHAGES INVITRO [J].
RAE, T .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1975, 57 (04) :444-450
[10]   THE TOXICITY OF METALS USED IN ORTHOPEDIC PROSTHESES - AN EXPERIMENTAL-STUDY USING CULTURED HUMAN SYNOVIAL FIBROBLASTS [J].
RAE, T .