POLYMERIC POROGENS USED IN THE PREPARATION OF NOVEL MONODISPERSED MACROPOROUS POLYMERIC SEPARATION MEDIA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:80
作者
WANG, QC [1 ]
HOSOYA, K [1 ]
SVEC, F [1 ]
FRECHET, JMJ [1 ]
机构
[1] CORNELL UNIV,DEPT CHEM,BAKER LAB,ITHACA,NY 14853
关键词
D O I
10.1021/ac00035a008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel approach to monosized macroporous polymeric separation media with vastly enhanced pore size distributions and chromatographic properties has been developed. Key to this approach is the combined use of monodispersed polymeric particles and suitable solvents as porogens in the copolymerization of styrene and divinylbenzene. Following polymerization, the polymeric porogen is dissolved, leaving behind the monosized beads with a controlled pore structure. The exact pore size and pore size distribution of the final beads are largely controlled by the amount of soluble polymer in the polymerizing mixture: the larger the proportion of soluble polymer in the system, the larger the pores. The uniformly sized macroporous beads prepared with an optimized ratio of polymeric and low molecular weight porogens proved to be very efficient even in short columns for the separation of polystyrene standards in the SEC mode and the separation of proteins in the reversed-phase mode. The relationship between pore size and specific surface area, on one hand, and chromatographic properties of the stationary phase, on the other, have been clearly documented.
引用
收藏
页码:1232 / 1238
页数:7
相关论文
共 27 条
  • [1] CHANG SH, 1976, J CHROMATOGR, V125, P103, DOI 10.1016/S0021-9673(00)93814-7
  • [2] MONOSIZED ADSORBENTS FOR HIGH-PERFORMANCE AFFINITY-CHROMATOGRAPHY - APPLICATION TO THE PURIFICATION OF CALF INTESTINAL ALKALINE-PHOSPHATASE AND HUMAN URINE UROKINASE
    CLONIS, YD
    LOWE, CR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 540 (1-2): : 103 - 111
  • [3] COLLIN H, 1989, HIGH PERFORMANCE LIQ, P455
  • [4] INFLUENCE OF THE PARTICLE-SIZE DISTRIBUTION OF THE PACKING MATERIAL IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEWAELE, C
    VERZELE, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1983, 260 (01): : 13 - 21
  • [5] MONOSIZED STATIONARY PHASES FOR CHROMATOGRAPHY
    ELLINGSEN, T
    AUNE, O
    UGELSTAD, J
    HAGEN, S
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 535 (1-2): : 147 - 161
  • [6] Guyot A., 1982, PROG POLYM SCI, V8, P277, DOI [10.1016/0079-6700(82)90002-8., DOI 10.1016/0079-6700(82)90002-8]
  • [7] GUYOT A, 1989, SYNTHESIS SEPARATION, P1
  • [8] HOSOYA K, UNPUB J LIQ CHROMATO
  • [9] MONOSIZED POLYMER PARTICLES IN SIZE-EXCLUSION CHROMATOGRAPHY .1. TOLUENE AS SOLVENT
    KULIN, LI
    FLODIN, P
    ELLINGSEN, T
    UGELSTAD, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 514 (01): : 1 - 9
  • [10] CHROMATOGRAPHIC EVALUATION OF LARGE-PORE AND NON-POROUS POLYMERIC REVERSED PHASES
    LEE, DP
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 443 : 143 - 153