AVIDIN AND (111) IN-LABELED BIOTIN SCAN - A NEW RADIOISOTOPIC METHOD FOR LOCALIZING VASCULAR GRAFT INFECTION

被引:12
作者
CHIESA, R
MELISSANO, G
CASTELLANO, R
ZAMORA, CF
ASTORE, D
SAMUEL, A
PAGANELLI, G
FAZIO, F
GROSSI, A
机构
[1] Institute for Cardiovascular and Respiratory Disease, Scientific Institute H. San Raffaele, University of Milano, Milano
[2] Institute of Nuclear Medicine, Scientific Institute H. San Raffaele, University of Milano, Milano
关键词
VASCULAR PROSTHESES; ARTERIAL GRAFT INFECTION; AVIDIN/BIOTIN SCAN;
D O I
10.1016/S1078-5884(05)80162-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To evaluate a new imaging technique, for diagnosis of prosthetic vascular graft infection. Avidin is a protein which accumulates nonspecifically at sites of inflammation or infection. Due to its extremely low dissociation constant with biotin sites of infection can be imaged, using avidin as a pre-target, followed by injection of In-111-labelled biotin. This technique is much simpler than the common scintigraphic methods which employ labelling of blood components and its target-to-background ratio is greater than the methods employing radiolabelled proteins. Design: Prospective clinical study. Setting: A single department of vascular surgery and one of nuclear medicine of a Northern Italian hospital. Materials: Between May 1993 and May 1994, 31 grafts in 26 patients were studied; the series included 23 men and three women with a mean age of 65.5 years (range 54-76 years). The prosthetic graft (Dacron -16, ePTFE-15) were: aortoaortic 5, aortobifemoral 15, aortoiliac 1, and femoropopliteal 10. Sixteen patients were suspected of having a vascular graft infection (Group A), the other 10 patients served as controls (Group B). 20 mg of Avidin were injected iv, followed 24 h later by i.v. injection of 500 mu g of Biotin labelled with 74 MBq of In-111. Chief outcome measures: Whole-body imaging teas performed at 10 min and 2 h post-injection, along with SPECT imaging when indicated. Scan results were correlated with the traditional imaging modalities and the clinical outcome of the patients. Main results: In Group A: two patients (three grafts) were excluded from the study, there were six true-positives, one false-positive and 11 true-negatives. Results in Group B: 10 true-negatives. The overall sensitivity was 100%, the specificity 95%, the accuracy 96%, the positive predictive value 86% nl?and the negative predictive value 100%. Conclusions: These data suggest that Avidin/In-111-lnbelled Biotin scintigraphy is a useful non invasive diagnostic method for early diagnosis of suspected prosthetic vascular graft infection.
引用
收藏
页码:405 / 414
页数:10
相关论文
共 30 条
[11]  
Rubin, Fischman, Needleman, Et al., Radiolabeled, nonspecific, policlonal human immunoglobulin in the detection of focal inflammation by scintigraphy: comparison with Gallium-67 citrate and technetium-99m-labeled albumin, J Nucl Med, 30, pp. 385-389, (1989)
[12]  
La Muraglia, Fischman, Strauss, Et al., Utility of the Indium 111-labeled human immunoglobulin G scan for the detection of focal vascular graft infection, J. Vasc Surg, 10, pp. 20-28, (1989)
[13]  
MCAfee, Cagne, Subramanian, Schneider, The localization of <sup>111</sup>In-leukocytes, <sup>67</sup>Ga-polyclonal IgG and other radioactive agents in acute focal inflammatory lesions, J Nucl Med, 32, pp. 2126-2131, (1991)
[14]  
Morrel, Tompkins, Fischman, Et al., Autoradiographic method for quantitation of radiolabeled proteins in tissues using <sup>111</sup>In, J Nucl Med, 30, pp. 1538-1545, (1989)
[15]  
Rusckowsky, Paganelli, Hnatowich, Virzi, Fogarasi, Fazio, Imaging infection/inflammation in patients with Streptavidin and radiolabeled biotin, J Nucl Med, 33, (1992)
[16]  
Rusckowski, Fritz, Hnatowich, Localization of infection using streptavidin and biotin: an alternative to nonspecific policlonal immunoglobulin, J Nucl Med, 33, pp. 1810-1815, (1992)
[17]  
Paganelli, Songini, Magnani, Et al., Pretargetted immunoscintigraphy with the avidin-biotin system: four years experience, J Nucl Med, 35, (1994)
[18]  
Schmitt, Bandyk, Pequet, Towne, Bacterial adherence to vascular prostheses. A determinant of graft infectivity, J Vasc Surg, 3, pp. 732-740, (1986)
[19]  
Bandyk, Bergamini, Kinney, Seabrook, Towne, In situ replacement of vascular prostheses infected by bacterial biofilms, J Vasc Surg, 13, pp. 575-583, (1991)
[20]  
Towne, Seabrook, Bandyk, Freischlag, Edmiston, In situ replacement of vascular prostheses infected by bacterial biofilms. Long term follow-up, J Vasc Surg, 19, pp. 226-235, (1994)