Diffusion-weighted imaging in tissues: Theoretical models

被引:122
作者
Szafer, A
Zhong, JH
Anderson, AW
Gore, JC
机构
[1] Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, Connecticut
关键词
D O I
10.1002/nbm.1940080704
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Typical diffusion measurements use Stejskal-Tanner pulsed gradient spin echo sequences to provide information about the average diffusion and displacement profiles of particles in a sample, To derive structural information, a measured displacement profile has to be related by means of a model to the physical and geometrical properties of the tissue, such as diffusion coefficients and shapes of semi-permeable membranes of compartments in the system, The behavior of the NMR signal and the measured ADC are greatly affected by the cellular architecture of a tissue, mainly because cellular membranes are relatively impermeable to water, For long diffusion times, and small signal attenuations, ADC is relatively insensitive to how it is measured, In general, however, ADC values are not readily interpreted unless the measuring conditions are specified in detail, For given measuring conditions, ADC depends on intra- and extracellular diffusion coefficients, membrane permeabilities, cell sizes and the cellular volume fraction, If intra- and extracellular T-2 relaxation rates are different enough, ADC may also depend on the relaxation properties of the system and the echo time, An improved understanding of the precise influence of these factors has been obtained by detailed consideration of theoretical and computer models that can be related to experimental data in simple systems, Further refinements of such models should advance our understanding of water diffusion in tissues.
引用
收藏
页码:289 / 296
页数:8
相关论文
共 45 条
[21]   EFFECTS OF FINITE GRADIENT-PULSE WIDTHS IN PULSED-FIELD-GRADIENT DIFFUSION MEASUREMENTS [J].
MITRA, PP ;
HALPERIN, BI .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1995, 113 (01) :94-101
[22]   DIFFUSION PROPAGATOR AS A PROBE OF THE STRUCTURE OF POROUS-MEDIA [J].
MITRA, PP ;
SEN, PN ;
SCHWARTZ, LM ;
LEDOUSSAL, P .
PHYSICAL REVIEW LETTERS, 1992, 68 (24) :3555-3558
[23]   EARLY DETECTION OF REGIONAL CEREBRAL-ISCHEMIA IN CATS - COMPARISON OF DIFFUSION-WEIGHTED AND T2-WEIGHTED MRI AND SPECTROSCOPY [J].
MOSELEY, ME ;
COHEN, Y ;
MINTOROVITCH, J ;
CHILEUITT, L ;
SHIMIZU, H ;
KUCHARCZYK, J ;
WENDLAND, MF ;
WEINSTEIN, PR .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :330-346
[24]   HINDERED DIFFUSION OF HIGH-MOLECULAR-WEIGHT COMPOUNDS IN BRAIN EXTRACELLULAR MICROENVIRONMENT MEASURED WITH INTEGRATIVE OPTICAL IMAGING [J].
NICHOLSON, C ;
TAO, L .
BIOPHYSICAL JOURNAL, 1993, 65 (06) :2277-2290
[25]   ION DIFFUSION MODIFIED BY TORTUOSITY AND VOLUME FRACTION IN THE EXTRACELLULAR MICRO-ENVIRONMENT OF THE RAT CEREBELLUM [J].
NICHOLSON, C ;
PHILLIPS, JM .
JOURNAL OF PHYSIOLOGY-LONDON, 1981, 321 (DEC) :225-257
[26]   ION-SELECTIVE MICROELECTRODES AND DIFFUSION MEASUREMENTS AS TOOLS TO EXPLORE THE BRAIN-CELL MICROENVIRONMENT [J].
NICHOLSON, C .
JOURNAL OF NEUROSCIENCE METHODS, 1993, 48 (03) :199-213
[27]  
NICHOLSON C, 1993, FUNCTIONAL MRI BRAIN, P1
[28]   DETECTION OF APPARENT RESTRICTED DIFFUSION IN HEALTHY RAT-BRAIN AT SHORT DIFFUSION TIMES [J].
NIENDORF, T ;
NORRIS, DG ;
LEIBFRITZ, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :672-677
[29]   INCIDENCE OF APPARENT RESTRICTED DIFFUSION IN 3 DIFFERENT MODELS OF CEREBRAL INFARCTION [J].
NORRIS, DG ;
NIENDORF, T ;
HOEHNBERLAGE, M ;
KOHNO, K ;
SCHNEIDER, EJ ;
HAINZ, P ;
HROPOT, M ;
LEIBFRITZ, D .
MAGNETIC RESONANCE IMAGING, 1994, 12 (08) :1175-1182
[30]   HEALTHY AND INFARCTED BRAIN-TISSUES STUDIED AT SHORT DIFFUSION TIMES - THE ORIGINS OF APPARENT RESTRICTION AND THE REDUCTION IN APPARENT DIFFUSION-COEFFICIENT [J].
NORRIS, DG ;
NIENDORF, T ;
LEIBFRITZ, D .
NMR IN BIOMEDICINE, 1994, 7 (07) :304-310