USE OF A POWER-CONSUMPTION-CONTROLLED EXTRUDER IN THE DEVELOPMENT OF PELLET FORMULATIONS

被引:31
作者
KLEINEBUDDE, P
机构
[1] Christian-Albrechts-University Kiel, Pharmaceutical Institute, Department of Pharmaceutics and Biopharmaceutics, Kiel, D-24118
关键词
D O I
10.1002/jps.2600841022
中图分类号
R914 [药物化学];
学科分类号
100701 [药物化学];
摘要
Shape is an important characteristic of pellets that is highly influenced by the water content of the extrudate during spheronization. The power-consumption-controlled extruder (pcc-extruder) is an appropriate tool to adjust the required water content to yield round pellets. For this purpose, it is necessary to run the extruder at a specific level of power consumption. in the first part of the study, this approach was employed to screen different drugs as well as excipients to prove the concept of the pcc-extruder. Usually round pellets were obtained but a few formulations did not produce round pellets. In the second part of the study, the influence of screw speed and powder feed rate on the required level of power consumption was investigated, A correlation between the water content and the shape of pellets was evident. To account for screw speed, it was necessary to adjust net power consumption instead of total power consumption. The influence of the screw speed on water content of extrudate and consequently on the shape of pellets was not significant in the studied range. Variations of the powder feed rate affected both the water content and the shape of pellets. However, the water content was not only dependent on the level of net power consumption. The specific power is the ratio of net power consumption to extrusion rate, and it correlates well with water content and pellet shape. Using the specific power, it is possible to adjust the net power consumption in response to changes in powder feed rate.
引用
收藏
页码:1259 / 1264
页数:6
相关论文
共 15 条
[1]
INSTRUMENTATION OF A GRAVITY FEED EXTRUDER AND THE INFLUENCE OF THE COMPOSITION OF BINARY AND TERNARY MIXTURES ON THE EXTRUSION FORCES [J].
BAERT, L ;
FANARA, D ;
DEBAETS, P ;
REMON, JP .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1991, 43 (11) :745-749
[2]
THE INFLUENCE OF MOISTURE-CONTENT ON THE PREPARATION OF SPHERICAL GRANULES OF BARIUM-SULFATE AND MICROCRYSTALLINE CELLULOSE [J].
BAINS, D ;
BOUTELL, SL ;
NEWTON, JM .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1991, 69 (03) :233-237
[3]
THE INFLUENCE OF LACTOSE PARTICLE-SIZE ON SPHERONIZATION OF EXTRUDATE PROCESSED BY A RAM EXTRUDER [J].
FIELDEN, KE ;
NEWTON, JM ;
ROWE, RC .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1992, 81 (2-3) :205-224
[4]
FIELDEN KE, 1992, ENCY PHARM TECHNOLOG, V5, P395
[5]
Ghebre-Selassie I., 1989, PHARM PELLETIZATION, VVolume 37, P1
[6]
HARPER JM, 1981, EXTRUSION FOOD, V1, P72
[7]
Harris MR, 1989, PHARM PELLETIZATION, P217
[8]
THE APPLICATION OF CAPILLARY RHEOMETRY TO THE EXTRUSION OF WET POWDER MASSES [J].
HARRISON, PJ ;
NEWTON, JM ;
ROWE, RC .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1987, 35 (03) :235-242
[9]
EXPERIMENTS WITH AN INSTRUMENTED TWIN-SCREW EXTRUDER USING A SINGLE-STEP GRANULATION EXTRUSION PROCESS [J].
KLEINEBUDDE, P ;
LINDNER, H .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1993, 94 (1-3) :49-58
[10]
SHRINKING AND SWELLING PROPERTIES OF PELLETS CONTAINING MICROCRYSTALLINE CELLULOSE AND LOW SUBSTITUTED HYDROXYPROPYLCELLULOSE .2. SHRINKING PROPERTIES [J].
KLEINEBUDDE, P .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1994, 109 (03) :209-219