DIRECT DETERMINATION OF ORGANIC-COMPOUNDS IN WATER AT PARTS-PER-QUADRILLION LEVELS BY MEMBRANE INTRODUCTION MASS-SPECTROMETRY

被引:82
作者
SONI, M
BAUER, S
AMY, JW
WONG, P
COOKS, RG
机构
[1] PURDUE UNIV,DEPT CHEM,W LAFAYETTE,IN 47907
[2] MIMS TECHNOL DEV INC,PALM BAY,FL 32906
关键词
D O I
10.1021/ac00104a016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parts-per-quadrillion level detection of toluene and trans-1,2-dichloroethene in water has been achieved on-line, without preconcentration, by employing selective ionization in conjunction with membrane introduction ion trap mass spectrometry. The stored wave form inverse Fourier transform technique is used to create broad-band wave forms, notched at the resonance frequencies of analyte ions of interest. A series of such pulses is applied during ionization to eject unwanted ions and store only analyte ions. This capability is used over long ionization times to obtain extraordinarily low detection limits for aqueous solutions of volatile organic compounds, introduced into the ion trap using a silicone membrane located within in a commercially available capillary membrane inlet system.
引用
收藏
页码:1409 / 1412
页数:4
相关论文
共 28 条
[21]   SELECTIVE INJECTION AND ISOLATION OF IONS IN QUADRUPOLE ION-TRAP MASS-SPECTROMETRY USING NOTCHED WAVE-FORMS CREATED USING THE INVERSE FOURIER-TRANSFORM [J].
SONI, MH ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :2488-2496
[22]   SINGLE-MOLECULE DETECTION OF RHODAMINE-6G IN ETHANOLIC SOLUTIONS USING CONTINUOUS WAVE LASER EXCITATION [J].
SOPER, SA ;
SHERA, EB ;
MARTIN, JC ;
JETT, JH ;
HAHN, JH ;
NUTTER, HL ;
KELLER, RA .
ANALYTICAL CHEMISTRY, 1991, 63 (05) :432-437
[23]   FLUORESCENCE DETECTION IN CAPILLARY ZONE ELECTROPHORESIS USING A CHARGE-COUPLED DEVICE WITH TIME-DELAYED INTEGRATION [J].
SWEEDLER, JV ;
SHEAR, JB ;
FISHMAN, HA ;
ZARE, RN ;
SCHELLER, RH .
ANALYTICAL CHEMISTRY, 1991, 63 (05) :496-502
[24]   INFLUENCE OF SPACE-CHARGE ON THE COMPUTED STATISTICAL PROPERTIES OF STORED IONS COOLED BY A BUFFER GAS IN A QUADRUPOLE RF TRAP [J].
VEDEL, F ;
ANDRE, J .
PHYSICAL REVIEW A, 1984, 29 (04) :2098-2101
[25]   ON-SITE ENVIRONMENTAL-ANALYSIS BY MEMBRANE INLET MASS-SPECTROMETRY [J].
VIRKKI, VT ;
KETOLA, RA ;
OJALA, M ;
KOTIAHO, T ;
KOMPPA, V ;
GROVE, A ;
FACCHETTI, S .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1421-1425
[26]  
Watson J.T., 1985, INTRO MASS SPECTROME
[27]  
WEBERGRAUBAU M, 1987, 35TH P ASMS C MASS S, P263
[28]   CHEMICAL-ANALYSIS OF SINGLE HUMAN ERYTHROCYTES [J].
YEUNG, ES .
ACCOUNTS OF CHEMICAL RESEARCH, 1994, 27 (12) :409-414