A REVIEW OF IMPEDANCE CARDIOGRAPHY

被引:58
作者
JENSEN, L
YAKIMETS, J
TEO, KK
机构
[1] Faculty of Nursing University of Alberta, Critical Care Nursing Program, Misericordia Hospital, Edmonton, Alta.
[2] Cardiac Clinical Trials Centre, University of Alberta Hospital, Edmonton, Alta.
来源
HEART & LUNG | 1995年 / 24卷 / 03期
关键词
D O I
10.1016/S0147-9563(05)80036-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To review the reliability and validity estimates of impedance cardiography to assess its empirical precision and clinical usefulness. Data Source: Empirical and theoretical literature mainly within the last 10 years. Data Synthesis: Descriptive statistics used to summarize the accuracy and use of impedance cardiography to estimate stroke volume. Conclusions: Estimation of cardiac output is presently a core component of optimizing cardiac function in many patient populations. Impedance cardiography, which initially used a formula developed by Kubicek et al. and recently a formula developed by Sramek and Bernstein, remains controversial with regard to its accuracy and use in research and clinical practice.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 114 条
[1]  
Bernstein, Noninvasive cardiac output measurement, Textbook of critical care medicine, pp. 159-185, (1989)
[2]  
Kubicek, Karnegis, Patterson, Witsoe, Mattson, Development and evaluation of an impedance cardiac output system, Acrospace Med, 37, pp. 1208-1212, (1966)
[3]  
Sherwood, Allen, Fahrenberg, Kelsey, Lovallo, van Doornen, Methodological guidelines for impedance cardiography, Psychophysiology, 27, pp. 1-23, (1990)
[4]  
Buell, A practical, cost-effective, noninvasive system for cardiac output and hemodynamic analysis, Am Heart J, 116, pp. 657-664, (1988)
[5]  
Harrell, Futrell, Adams, Forst, Sherwood, Hutcheson, Cardiac output and associated cardiovascular responses to bed making, Crit Care Nursing Q, 12, pp. 19-33, (1989)
[6]  
Kubicke, On the source of peak first time derivative (dZ/dt) during impedance cardiography, Annals of Biomedical Engineering, 17, pp. 459-462, (1989)
[7]  
Sheps, Petrovick, Kizakevich, Wolfe, Craige, Continuous noninvasive monitoring of left ventricular function during exercise by thoracic impedance cardiography-automated derivation of systolic time intervals, Am Heart J, 103, pp. 519-524, (1982)
[8]  
World, Estimation of cardiac output by impedance cardiography, J Roy Army Med Corps, 136, 2, pp. 92-99, (1990)
[9]  
Bernstein, A new stroke volume equation for thoracic electrical bioimpedance: theory and rationale, Crit Care Med, 14, pp. 904-909, (1986)
[10]  
Bunnell, Non-invasive measurement of sympathetic influences on the heart, Psychophysiology of cardiovascular control: models, methods, and data, pp. 221-235, (1985)