A REVIEW OF IMPEDANCE CARDIOGRAPHY

被引:58
作者
JENSEN, L
YAKIMETS, J
TEO, KK
机构
[1] Faculty of Nursing University of Alberta, Critical Care Nursing Program, Misericordia Hospital, Edmonton, Alta.
[2] Cardiac Clinical Trials Centre, University of Alberta Hospital, Edmonton, Alta.
来源
HEART & LUNG | 1995年 / 24卷 / 03期
关键词
D O I
10.1016/S0147-9563(05)80036-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To review the reliability and validity estimates of impedance cardiography to assess its empirical precision and clinical usefulness. Data Source: Empirical and theoretical literature mainly within the last 10 years. Data Synthesis: Descriptive statistics used to summarize the accuracy and use of impedance cardiography to estimate stroke volume. Conclusions: Estimation of cardiac output is presently a core component of optimizing cardiac function in many patient populations. Impedance cardiography, which initially used a formula developed by Kubicek et al. and recently a formula developed by Sramek and Bernstein, remains controversial with regard to its accuracy and use in research and clinical practice.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 114 条
[31]  
Niizeki, Miyamoto, Doi, A comparison between cardiac output determined by impedance cardiography and the rebreathing method during exercise in man, Jpn J Physiol, 39, pp. 441-446, (1989)
[32]  
Teo, Hetherington, Haennel, Greenwood, Rossall, Kappagoda, Cardiac output measured by impedance cardiography during maximal exercise tests, Cardiovasc Res, 19, pp. 737-743, (1985)
[33]  
Wilson, Sung, Pincomb, Lovallo, Simultaneous measurement of stroke volume by impedance cardiography and nuclear ventriculography: comparisons at rest and exercise, Ann Biomed Eng, 17, pp. 475-482, (1989)
[34]  
Fuller, The validity of cardiac output measurement by thoracic impedance: a meta-analysis, Clin Invest Med, 15, pp. 103-112, (1992)
[35]  
Qu, Zhang, Webster, Tompkins, Motion artifact from spot and band electrodes during impedance cardiography, IEEE Trans Biomed Eng, 33, pp. 1029-1035, (1986)
[36]  
Miles, Gotshall, Quinones, Wulfeck, Kreitzer, Impedance cardiography fails to measure accurately left ventricular ejection fraction, Critical Care Medicine, 36, pp. 221-228, (1990)
[37]  
Miles, Gotshall, Quinones, Wulfeck, Kreitzer, Impedance cardiography fails to measure accurately left ventricular ejection fraction, Crit Care Med, 18, pp. 221-228, (1990)
[38]  
Ekman, Milson, Arvidsson, Biber, Martinell, Sjoqvist, Clinical evaluation of an ensemble-averaging impedance cardiograph for monitoring stroke volume during spontaneous breathing, Acta Anaesthesiol Scand, 34, pp. 190-196, (1990)
[39]  
Gotshall, Miles, Noninvasive assessment of cardiac output by impedance cardiography in the newborn canine, Crit Care Med, 17, pp. 63-65, (1989)
[40]  
Kiesler, Voorhees, Wessale, Pham, Impedance cardiography by use of a spot-electrode array to track changes in cardiac output in anesthetized dogs, J Am Vet Med Assoc, 196, pp. 1804-1810, (1990)