Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials

被引:88
作者
Abdulkarim, Ali [1 ,2 ]
Ellanti, Prasad [1 ,2 ]
Motterlini, Nicola [1 ,2 ]
Fahey, Tom [1 ,2 ]
O'Byrne, John M. [1 ,2 ]
机构
[1] Cappagh Natl Orthopaed Hosp, Dept Orthopaed, Dublin 11, Ireland
[2] Royal Coll Surg, Dublin, Ireland
关键词
cemented; uncemented; total hip arthroplasty; meta analysis;
D O I
10.4081/or.2013.e8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The optimal method of fixation for primary total hip replacements (THR), particularly fixation with or without the use of cement is still controversial. In a systematic review and metaanalysis of all randomized controlled trials comparing cemented versus uncemented THRS available in the published literature, we found that there is no significant difference between cemented and uncemented THRs in terms of implant survival as measured by the revision rate. Better short-term clinical outcome, particularly an improved pain score can be obtained with cemented fixation. However, the results are unclear for the long-term clinical and functional outcome between the two groups. No difference was evident in the mortality and the post operative complication rate. On the other hand, the radiographic findings were variable and do not seem to correlate with clinical findings as differences in the surgical technique and prosthesis design might be associated with the incidence of osteolysis. We concluded in our review that cemented THR is similar if not superior to uncemented THR, and provides better short term clinical outcomes. Further research, improved methodology and longer follow up are necessary to better define specific subgroups of patients in whom the relative benefits of cemented and uncemented implant fixation can be clearly demonstrated.
引用
收藏
页码:34 / 44
页数:11
相关论文
共 62 条
[1]
Altman DG, 1996, BRIT MED J, V313, P570
[2]
AMSTUTZ HC, 1988, ORTHOP CLIN N AM, V19, P491
[3]
Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements - Factors affecting survivorship of acetabular and femoral components [J].
Berry, DJ ;
Harmsen, WS ;
Cabanela, ME ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (02) :171-177
[4]
Direct comparison of polyethylene wear in cemented and uncemented acetabular cups [J].
Bjerkholt H. ;
Høvik Ø. ;
Reikerås O. .
Journal of Orthopaedics and Traumatology, 2010, 11 (3) :155-158
[5]
No differences in outcomes between cemented and uncemented acetabular components after 12-14 years: Results from a randomized controlled trial comparing Duraloc with Charnley cups [J].
Bjørgul K. ;
Novicoff W.M. ;
Andersen S.T. ;
Brevig K. ;
Thu F. ;
Wiig M. ;
Åhlund O. .
Journal of Orthopaedics and Traumatology, 2010, 11 (1) :37-45
[6]
Factors affecting aseptic loosening of 4750 total hip arthroplasties: multivariate survival analysis [J].
Bordini, Barbara ;
Stea, Susanna ;
De Clerico, Manuela ;
Strazzari, Sergio ;
Sasdelli, Antonio ;
Toni, Aldo .
BMC MUSCULOSKELETAL DISORDERS, 2007, 8 (1)
[7]
Bourne R B, 1994, Iowa Orthop J, V14, P108
[8]
CARLSSON AS, 1984, CLIN ORTHOP RELAT R, P145
[9]
Furlong Hydroxyapatite-Coated Hip Prosthesis vs the Charnley Cemented Hip Prosthesis [J].
Chandran, Prakash ;
Azzabi, Mohamed ;
Miles, Jeremy ;
Andrews, Mark ;
Bradley, John .
JOURNAL OF ARTHROPLASTY, 2010, 25 (01) :52-57
[10]
SURGERY OF THE HIP-JOINT - PRESENT AND FUTURE DEVELOPMENTS [J].