DETERMINATION OF THE MOST APPROPRIATE VELOCITY THRESHOLD FOR APPLYING HEMISPHERIC FLOW CONVERGENCE EQUATIONS TO CALCULATE FLOW-RATE - SELECTED ACCORDING TO THE TRANSORIFICE PRESSURE-GRADIENT - DIGITAL-COMPUTER ANALYSIS OF THE DOPPLER COLOR-FLOW CONVERGENCE REGION

被引:49
作者
DENG, YB [1 ]
SHIOTA, T [1 ]
SHANDAS, R [1 ]
ZHANG, J [1 ]
SAHN, DJ [1 ]
机构
[1] OREGON HLTH SCI UNIV,CLIN CARE CTR CONGENITAL HEART DIS,3181 SW SAM JACKSON PK RD UHN60,PORTLAND,OR 97201
关键词
FLOW; ECHOCARDIOGRAPHY;
D O I
10.1161/01.CIR.88.4.1699
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. While flow convergence methods have been promising for calculating volume flows from color Doppler images, it appears that the velocity threshold used and the transorifice pressure gradient dramatically influence the accuracy of application of the simple hemispheric flow convergence equation for calculation of flow rate. The present in vitro study was performed to determine whether the value of velocity threshold at which the shape of proximal isovelocity surface best fits given shape assumptions with different orifice sizes and flow rates is predictable as a function independent of orifice size from clinically measurable peak velocity or transorifice pressure gradient information. Methods and Results. In an in vitro model built to facilitate ultrasound imaging, steady flow was driven through circular discrete orifices with diameters of 3.8, 5.5, and 10 mm. Flow rates ranged from 2.88 to 8.28 L/min with corresponding driving pressure gradients from 14 to 263 mm Hg. At each flow rate, Doppler color-encoded M-mode images through the center of the flow convergence region were obtained and transferred into the microcomputer (Macintosh IIci) in their original digital format. Then, the continuous wave Doppler traces of maximal velocity through the orifice were derived for the calculation of driving pressure gradient. Direct numerical spatial velocity measurements were obtained from the digital color encoded M-mode velocities with computer software. For each flow rate, we could calculate flow volume from any number of velocity distance combinations with a number of assumptions and use the results to assess, expected flow convergence shape based on a priori knowledge of the progression from oblate hemispheroid to hemisphere to prolate hemispheroid changes observed previously. Our results showed that for a given ratio of calculated flow rate to actual flow rate (0.7 and 1), the velocity threshold that could be used for the calculation of flow rate with a hemispheric flow convergence equation correlated well with the pressure gradient for a given orifice size, and the differences in velocity threshold that could be used this way among different orifice sizes once they were adjusted for the covariate pressure gradients were not statistically significant (P=.79 for ratio=0.7, and P=.81 for ratio=1). Conclusions. Our present study provides an orifice size-independent quantitative method that can be used to select the most suitable velocity threshold for applying a simple hemispheric flow convergence equation based on clinically predictable pressure gradients ranging from 40 to 200 mm Hg, and it offers a correction factor that can be applied to the hemispheric flow convergence equation when the pressure gradient is less than 40 mm Hg.
引用
收藏
页码:1699 / 1708
页数:10
相关论文
共 33 条
  • [1] BARCLAY SA, 1991, CIRCULATION S2, V84, P105
  • [2] A NEW METHOD FOR QUANTITATION OF MITRAL REGURGITATION BASED ON COLOR FLOW DOPPLER IMAGING OF FLOW CONVERGENCE PROXIMAL TO REGURGITANT ORIFICE
    BARGIGGIA, GS
    TRONCONI, L
    SAHN, DJ
    RECUSANI, F
    RAISARO, A
    DESERVI, S
    VALDESCRUZ, LM
    MONTEMARTINI, C
    [J]. CIRCULATION, 1991, 84 (04) : 1481 - 1489
  • [3] COLOR DOPPLER DIAGNOSIS OF MECHANICAL PROSTHETIC MITRAL REGURGITATION - USEFULNESS OF THE FLOW CONVERGENCE REGION PROXIMAL TO THE REGURGITANT ORIFICE
    BARGIGGIA, GS
    TRONCONI, L
    RAISARO, A
    RECUSANI, F
    RAGNI, T
    VALDESCRUZ, LM
    SAHN, DJ
    MONTEMARTINI, C
    [J]. AMERICAN HEART JOURNAL, 1990, 120 (05) : 1137 - 1142
  • [4] CHEN C, 1991, CIRCULATION S2, V84, P637
  • [5] CRANNEY G, 1991, CIRCULATION S2, V84, P203
  • [6] COLOR DOPPLER DETERMINATION OF REGURGITANT FLOW - FROM PROXIMAL ISOVELOCITY SURFACE-AREAS TO PROXIMAL VELOCITY PROFILES - AN INVITRO STUDY
    GIESLER, MO
    STAUCH, M
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1992, 9 (01): : 51 - 62
  • [7] HATLE L, 1980, BRIT HEART J, V43, P284
  • [8] LEVINE R A, 1991, Journal of the American College of Cardiology, V17, p359A
  • [9] MOISES V A, 1990, Journal of the American College of Cardiology, V15, p109A
  • [10] A NEW METHOD FOR NONINVASIVE ESTIMATION OF VENTRICULAR SEPTAL-DEFECT SHUNT FLOW BY DOPPLER COLOR FLOW MAPPING - IMAGING OF THE LAMINAR-FLOW CONVERGENCE REGION ON THE LEFT SEPTAL SURFACE
    MOISES, VA
    MACIEL, BC
    HORNBERGER, LK
    MURILLOOLIVAS, A
    VALDESCRUZ, LM
    SAHN, DJ
    WEINTRAUB, RG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) : 824 - 832