NORMALIZATION OF MULTISPECTRAL DATA IN POSITRON EMISSION TOMOGRAPHY

被引:7
作者
MSAKI, P
BENTOURKIA, M
CADORETTE, J
HEON, M
LECOMTE, R
机构
[1] Dept. of Nucl. Med. and Radiobiol., Sherbrooke Univ., Que.
关键词
D O I
10.1088/0031-9155/38/12/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Data acquisition using more than one energy window has been proposed principally for scatter correction in positron emission tomography (PET). However, prior to scatter correction, such data must be corrected for various distortions including detector efficiency and spectral non-uniformities. The aim of this work is to describe and validate a normalization technique that can minimize these undesirable effects. As with conventional methods using broad windows, the technique reduces the non-uniformity of data acquired in several narrow windows. while performing an additional task unique to multispectral acquisition, i.e. to restore symmetry in data acquired by mirror window pairs of individual detectors. Non-uniformity and asymmetry reductions have been achieved by averaging each pair of detectors over all detectors and averaging each mirror window pair, respectively. The method has been validated using data with different degrees of spatial and spectral distortion, and has been found to be capable of restoring the greatest spectral asymmetric acquisition possible with our animal PET system. Unlike the broad-window imaging, a match of spectral composition of photon fluence between the calibration and measurements is not a requirement. In conclusion, multispectral data acquisition in PFT is possible with fairly non-uniform detector response. The success of the technique, however, depends on detectors with very stable characteristics.
引用
收藏
页码:1745 / 1760
页数:16
相关论文
共 23 条
[1]   TUNING OF AVALANCHE PHOTODIODE PET CAMERA [J].
CADORETTE, J ;
RODRIGUE, S ;
LECOMTE, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1062-1066
[2]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[3]   QUANTITATIVE ASSESSMENT OF FIELD UNIFORMITY FOR GAMMA CAMERAS [J].
COHEN, G ;
KEREIAKES, JG ;
PADIKAL, TN ;
ASHARE, AB ;
SAENGER, EL .
RADIOLOGY, 1976, 118 (01) :197-200
[4]   NUMERICAL INDEX OF GAMMA-CAMERA UNIFORMITY [J].
COX, NJ ;
DIFFEY, BL .
BRITISH JOURNAL OF RADIOLOGY, 1976, 49 (584) :734-735
[5]   A NORMALIZATION TECHNIQUE FOR 3D PET DATA [J].
DEFRISE, M ;
TOWNSEND, DW ;
BAILEY, D ;
GEISSBUHLER, A ;
MICHEL, C ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :939-952
[6]   AN INVESTIGATION OF METHODS OF PILEUP REJECTION FOR 2-D ARRAY DETECTORS EMPLOYED IN HIGH-RESOLUTION PET [J].
GERMANO, G ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (02) :223-227
[7]  
GROOTOONK S, 1991, 1991 IEEE NUCL SCI S, V3, P1569
[8]  
HARRISON RL, 1991, 1991 IEEE NUCL SCI S, V3, P1700
[9]   PET SYSTEM CALIBRATIONS AND CORRECTIONS FOR QUANTITATIVE AND SPATIALLY ACCURATE IMAGES [J].
HOFFMAN, EJ ;
GUERRERO, TM ;
GERMANO, G ;
DIGBY, WM ;
DAHLBOM, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1108-1112
[10]   FACTORS AFFECTING GAMMA-CAMERA NON-UNIFORMITY [J].
HUGHES, A ;
SHARP, PF .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (02) :259-269